Parameters
Address (H)
Initial
Settings
Sys. Para.
List
ADF
Printer
DEC (1 - 255; 0 = Disabled)
8001DD
8001E1
10 (H)
X
CALL (3 - 15; 0 = Disabled)
8001DE
8001E2
06 (H)
Y
CLR
(Low)
(High)
8001DF
8001E3
30 (H)
—
8001E0
8001E4
00 (H)
Counters
Address (H)
Sys. Para. List
ADF
Printer
JAM: Jam counter used to place a
service call
8001D6
8001DA
Z
NO-JAM1: Counter used for JAM
counter decrement
8001D5
8001D9
—
NO-JAM2: Counter used for clear-
ing the JAM counter
8001D7 (Low)
8001DB (Low)
—
8001D8 (High)
8001DC (High)
The system parameter list gives the current DEC and CALL thresholds and
JAM counter value as X, Y, and Z respectively.
The Call Service indicator does not light for an excessive jam alarm, and the
machine can be operated normally after the automatic service call has been
made. Also, the counters related to the jam location are reset to zero automat-
ically after the call. Then the alarm is disabled until either bit 3 or bit 4 of
address 80033d is reset to zero.
3. Periodic Service Call
The periodic service call notifies the condition of the machine to the service
station. The call is made periodically at a time interval programmed in the fol-
lowing RAM addresses.
Parameters
Address (H)
Call interval: 01 through 15 month(s) (BCD)
00: Periodic Service Call Disabled
800256
Date and time of the next call
Year: last two digits of the year (BCD)
800257
Month: 01 through 12 (BCD)
800258
Day: 01 through 31 (BCD)
800259
Hour: 00 through 23 (BCD)
80025A
To change these settings after programming, change the call interval. Then
the machine automatically changes the remaining parameters by referring to
the interval and the current date and time.
The Call Service indicator does not light for a periodic service call, so that the
machine can be operated normally after it has sent the service call.
May 22nd, 1995
DETAILED SECTION DESCRIPTIONS
SYSTEM FEATURES
2-69