4.5. SERVICE RAM ADDRESSES
I
CAUTION
Do not change the settings which are marked as “Not used” or “Read
only.”
800000(H) - RAM Reset Level 1
Change the data at this address to 00 (H), then switch the machine off and on to reset all the
system settings.
I
CAUTION
Before using this RAM, print the settings of all the system parameters
(System Parameter List).
800001 to 800004(H) - ROM version (Read only)
800001(H) - Revision number (BCD)
800002(H) - Year (BCD)
800003(H) - Month (BCD)
800004(H) - Day (BCD)
800006 to 800016(H) - Machine’s serial number (17 digits - ASCII)
800018(H) - Total program checksum (low)
800019(H) - Total program checksum (high)
80001A(H) - Boot program checksum (low)
80001B(H) - Boot program checksum (high)
80001C(H) - Main program checksum (low)
80001D(H) - Main program checksum (high)
80001E(H) - RDS program update counter (Hex)
800020 to 80003F(H) - System bit switches
800040 to 80004F(H) - Scanner bit switches
800050 to 80005F(H) - Printer bit switches
800060 to 80007F(H) - Communication bit switches
800080 to 80008F(H) - G3 bit switches
8000A0(H) - User parameter switch 00
Bit 0: Stamp home position 0: Disabled, 1: Enabled
Bits 1 and 2: Scanning contrast home position
Bit 2 1 Setting
0 0 Normal
0 1 Lighten
1 0 Darken
Bit 3: Do not adjust
Bits 4 and 5: Scanning resolution home position
Bit 5 4 Setting
0 0 Standard
0 1 Detail
1 0 Fine
Bit 6: Transmission mode home position 0: Memory tx, 1: Immediate tx
Bit 7: Halftone home position 0: Disabled, 1: Enabled
May 22nd, 1995
SERVICE TABLES AND PROCEDURES
SERVICE RAM ADDRESSES
4-75