System Switch 03
No
FUNCTION
COMMENTS
0
to
7
Length of time that RDS is
temporarily switched on
when bits 6 and 7 of
System Switch 02 are set to
"User selectable"
00 - 99 hours (BCD).
This data is only valid if bits 6 and 7 of System Switch
02 are set to "User selectable".
System Switch 04
No
FUNCTION
COMMENTS
0
1
2
LCD contrast
Bit 2 1 0 Contrast
0 0 0 Brightest
0 0 1
↓
↓
↓
1 1 0
↓
1 1 1 Darkest
Use these bit switches to adjust the contrast of the
LCD on the operation panel.
3
Dedicated transmission
parameter programming
0: Disabled 1: Enabled
This bit must be set to 1 before changing any
dedicated transmission parameters
4
Not used
Do not change the factory setting.
5
OPC (master drum)
replacement level
0: User
1: Service
0: The machine asks the user to replace the OPC
drum at 30,000 print intervals (default interval).
After the user replaces the drum, the machine asks the
user if the drum is replaced or not. If the user answers
yes, the machine resets the OPC counter to zero. The
drum replacement interval is programmed at
addresses 8001E5 to 8001E7(H). Refer to section 4.5
for more details.
1: The machine will not ask the user to replace the
drum.
6
CSI programming level
0: User level
1: Service level
1: The CSI can only be programmed using a service
function.
7
Telephone line type
programming mode
0: User level
1: Service level
1: Telephone line type can only be selected with a
service function.
System Switch 05
No
FUNCTION
COMMENTS
0
Not used
Do not change the settings.
1
2
Display of both RTI and CSI
on the LCD
0: Disabled 1: Enabled
1: Both RTI and CSI will be displayed alternately on
the LCD.
SERVICE TABLES AND PROCEDURES
May 22nd, 1995
BIT SWITCHES
4-22