19.8.3
CONTROLS AND INDICATORS
Figure 19-21 shows the location of all controls and indicators on the Skewed Hybrid module. These
controls and indicators are described in Table 19-9. Only R4 and R6 are accessible with the Skewed
Hybrid Module installed in the chassis. All others are accessible only when the module is removed
from the chassis.
TP4
TP3
TP2
TP6
R4
R6
TP5
TP1
Figure 19-21. Controls and indicators, RFL 9785 Skewed Hybrid I/O
Table 19-9. Controls and Indicators, RFL 9785 Skewed Hybrid I/O.
Component
Designator
Name/Description Function
R6
Potentiometer
Coarse adjustment for balancing network
R4
Potentiometer
Fine adjustment for balancing network
TP1
Test point
Send High (orange)
TP2
Test point
Send Low (orange)
TP3
Test point
Receive High (orange)
TP4
Test point
Receive low (orange)
TP5
Test point
Line High (orange)
TP6
Test point
Line Low (orange)
RFL 9785
RFL Electronics Inc.
September 1, 2006
19-38