Code
Name
Setting range
Default
Min.
Attri.
Frequency detection level
FDT2 width
0.01...[E2.73] Hz
1.00
0.01
Run
Counter middle value
0...[E2.81]
0
1
Run
Counter target value
[E2.80]...9,999
0
1
Run
Setting range of E2.01 (0...19) and E2.15 (0...18):
0: Converter ready
1: Converter running
2: Converter DC-braking
3: Converter running at zero speed
4: Speed arrival
5: Frequency level detection signal (FDT1)
6: Frequency level detection signal (FDT2)
7: Simple PLC stage complete
8: Simple PLC cycle complete
10: Converter undervoltage
11: Converter overload pre-warning
12: Motor overload pre-warning
13: Converter stop by external error
14: Converter error
15: Converter OK
16: Counter target value arrival
17: Counter middle value arrival
18: PID reference engineering value arrival
19: Pulse output mode enable (only available with DO1 output selection)
20: Torque control mode
99: Inactive
Bosch Rexroth AG
Appendix
EFC x610 Series
346/389
DOK-RCON03-EFC-X610***-IT05-EN-P