Message start
Transmission time for 3.5 bytes
Slave address
01H
Modbus function code
17H
Higher byte of read register start address
30H
Lower byte of read register start address
00H
Higher byte of read register number
00H
Lower byte of read register number
02H
Higher byte of write register start address
40H
Lower byte of write register start address
00H
Higher byte of write register number
00H
Lower byte of write register number
02H
Bytes of data for writing
04H
Higher byte of data in register 4000H
00H
Lower byte of data in register 4000H
01H
Higher byte of data in register 4001H
00H
Lower byte of data in register 4001H
00H
CRC lower byte
E6H
CRC higher byte
B3H
Message end
Transmission time for 3.5 bytes
Tab. 14-20: Function 0x17_Request from RTU master
Message start
Transmission time for 3.5 bytes
Slave address
01H
Modbus function code
17H
Bytes of read register
04H
Higher byte of read register 3000H
00H
Lower byte of read register 3000H
14H
Higher byte of read register 3001H
00H
Lower byte of read register 3001H
02H
CRC lower byte
38H
CRC higher byte
E2H
Message end
Transmission time for 3.5 bytes
Tab. 14-21: Function 0x17_Response from RTU slave
EFC x610 Series
Bosch Rexroth AG
Communication
DOK-RCON03-EFC-X610***-IT05-EN-P
265/389
Содержание EFC 3610 Series
Страница 18: ...Bosch Rexroth AG EFC x610 Series XVI DOK RCON03 EFC X610 IT05 EN P ...
Страница 332: ...Fig 15 15 0020 N 03_0025 N 03 Bosch Rexroth AG Accessories EFC x610 Series 300 389 DOK RCON03 EFC X610 IT05 EN P ...
Страница 333: ...Fig 15 16 0025 A 05 EFC x610 Series Bosch Rexroth AG Accessories DOK RCON03 EFC X610 IT05 EN P 301 389 ...
Страница 336: ...Fig 15 21 0250 N 05 Bosch Rexroth AG Accessories EFC x610 Series 304 389 DOK RCON03 EFC X610 IT05 EN P ...
Страница 421: ...Notes EFC x610 Series Bosch Rexroth AG ...