19.6.2 Installation
Terminal Definition
Connection
Signal name
Function
1
COM
COM is the reference of +24 V
2
STO1+
Input channel 1
3
STO1-
The reference of Input channel 1
4
STO2+
Input channel 2
5
STO2-
The reference of Input channel 2
6
+24 V
Power supply
Tab. 19-4: Terminal definition
Cable Definition
Cable
Unit
Min.
Max.
Type
2*2 cables, low voltage, single shielded, twisted pair
Wire-end ferrule w/plastic collar (for STO terminal)
Cross-section
mm
2
1
1
AWG
17
17
Ferrule length
mm
12
12
Stripped length
mm
15
15
Wire-end ferrule w/o plastic collar (for STO terminal)
Cross-section
mm
2
1
1.5
AWG
17
16
Ferrule length
mm
10
10
Stripped length
mm
10
10
Tab. 19-5: Cable definition