if the setting frequency of next stage is higher than that of the current stage, it
will accelerate to the next stage with the acceleration time of next stage.
Code
Name
Setting range
Default
Min.
Attri.
E0.07 Digital setting frequency
0.00...[E0.09] Hz
50.00
0.01
Run
E3.40 Multi-speed frequency 1
0.00...[E0.09] Hz
0.00
0.01
Run
E3.41 Multi-speed frequency 2
0.00...[E0.09] Hz
0.00
0.01
Run
E3.42 Multi-speed frequency 3
0.00...[E0.09] Hz
0.00
0.01
Run
E3.43 Multi-speed frequency 4
0.00...[E0.09] Hz
0.00
0.01
Run
E3.44 Multi-speed frequency 5
0.00...[E0.09] Hz
0.00
0.01
Run
E3.45 Multi-speed frequency 6
0.00...[E0.09] Hz
0.00
0.01
Run
E3.46 Multi-speed frequency 7
0.00...[E0.09] Hz
0.00
0.01
Run
E3.47 Multi-speed frequency 8
0.00...[E0.09] Hz
0.00
0.01
Run
E3.48 Multi-speed frequency 9
0.00...[E0.09] Hz
0.00
0.01
Run
E3.49 Multi-speed frequency 10
0.00...[E0.09] Hz
0.00
0.01
Run
E3.50 Multi-speed frequency 11
0.00...[E0.09] Hz
0.00
0.01
Run
E3.51 Multi-speed frequency 12
0.00...[E0.09] Hz
0.00
0.01
Run
E3.52 Multi-speed frequency 13
0.00...[E0.09] Hz
0.00
0.01
Run
E3.53 Multi-speed frequency 14
0.00...[E0.09] Hz
0.00
0.01
Run
E3.54 Multi-speed frequency 15
0.00...[E0.09] Hz
0.00
0.01
Run
Step 4: Set the acceleration time / deceleration time, rotation direction for each
stage
EFC x610 Series
Bosch Rexroth AG
Functions and Parameters
DOK-RCON03-EFC-X610***-IT05-EN-P
137/389
Содержание EFC 3610 Series
Страница 18: ...Bosch Rexroth AG EFC x610 Series XVI DOK RCON03 EFC X610 IT05 EN P ...
Страница 332: ...Fig 15 15 0020 N 03_0025 N 03 Bosch Rexroth AG Accessories EFC x610 Series 300 389 DOK RCON03 EFC X610 IT05 EN P ...
Страница 333: ...Fig 15 16 0025 A 05 EFC x610 Series Bosch Rexroth AG Accessories DOK RCON03 EFC X610 IT05 EN P 301 389 ...
Страница 336: ...Fig 15 21 0250 N 05 Bosch Rexroth AG Accessories EFC x610 Series 304 389 DOK RCON03 EFC X610 IT05 EN P ...
Страница 421: ...Notes EFC x610 Series Bosch Rexroth AG ...