C2: V/f control parameters
Code
Name
Setting range
Default
Min.
Attri.
V/f curve mode
0: Linear
1: Square
2: User-defined
0
–
Stop
V/f frequency 1
0.00...[C2.03] Hz
0.00
0.01
Stop
V/f voltage 1
①
0.0...120.0 %
0.0
0.1
Stop
V/f frequency 2
[C2.01]...[C2.05] Hz
0.00
0.01
Stop
V/f voltage 2
①
0.0...120.0 %
0.0
0.1
Stop
V/f frequency 3
[C2.03]...[E0.08] Hz
50.00
0.01
Stop
V/f voltage 3
①
0.0...120.0 %
100.0
0.1
Stop
Slip compensation factor
0…200 %
0
1
Run
Torque boost setting
0.0 %: Automatic boost
0.1...20.0 %: Manual boost
0.0
0.1
Run
Automatic torque boost factor 0...320 %
50
1
Run
Heavy load stabilization
setting
0: Inactive
1: Active
1
–
Run
Light load oscillation damping
factor
0...5,000 %
0
1
Run
Light load oscillation damping
filter factor
10...2,000 %
100
1
Run
Current limitation mode
0: Always inactive
1: Inactive at constant speed
2: Active at constant speed
2
–
Stop
Current limitation level
②
[C0.27]...250 %
150
1
Stop
Current limitation
proportional gain
0.000...10.000
DOM
0.001
Stop
Current limitation
integral time
0.001...10.000
DOM
0.001
Stop
①
: percentage of motor rated voltage [C1.06].
②
: percentage of frequency converter rated current.
EFC x610 Series
Bosch Rexroth AG
Appendix
DOK-RCON03-EFC-X610***-IT05-EN-P
337/389
Содержание EFC 3610 Series
Страница 18: ...Bosch Rexroth AG EFC x610 Series XVI DOK RCON03 EFC X610 IT05 EN P ...
Страница 332: ...Fig 15 15 0020 N 03_0025 N 03 Bosch Rexroth AG Accessories EFC x610 Series 300 389 DOK RCON03 EFC X610 IT05 EN P ...
Страница 333: ...Fig 15 16 0025 A 05 EFC x610 Series Bosch Rexroth AG Accessories DOK RCON03 EFC X610 IT05 EN P 301 389 ...
Страница 336: ...Fig 15 21 0250 N 05 Bosch Rexroth AG Accessories EFC x610 Series 304 389 DOK RCON03 EFC X610 IT05 EN P ...
Страница 421: ...Notes EFC x610 Series Bosch Rexroth AG ...