40: Counter reset
41: PID deactivation
46: User parameter set selection
I/O card digital input status is monitored by parameter d0.43 'I/O
card digital input'.
Set analog input terminals
Code
Name
Setting range
Default Min.
Attri.
H8.05 EAI input mode
0: 0...20 mA
1: 4...20 mA
2: 0…10 V
3: 0…5 V
4: 2...10 V
5: -10...10 V
0
–
Stop
H8.06 EAI input polarity setting
0: Polarity inactive
1: Polarity active without direction
control
2: Polarity active with direction con-
trol
1
–
Stop
H8.08 EAI curve selection
0: Curve 0
1: Curve 1
2: Curve 2
1
–
Stop
H8.09 EAI filter time
0.000...2.000
0.100 0.001 Run
H8.10 EAI gain
0.00...10.00
1.00
0.01
Run
H8.15 Input curve 0 minimum
-120.0 %...[H8.17]
0.0
0.1
Run
H8.16 Input curve 0 minimum fre-
quency
-[E0.09]...[E0.09] Hz
0.00
0.01
Run
H8.17 Input curve 0 maximum
[H8.15]...120.0 %
100.0
0.1
Run
H8.18 Input curve 0 maximum fre-
quency
-[E0.09]...[E0.09] Hz
50.00 0.01
Run
Except for an additional option of '-10…10 V', EAI is the same as AI1 and AI2.
In order to use '-10…10 V', set [H8.05] = '-10…10 V' first.
EAI can use any of the curve configuration by setting H8.08 parameter to '0:
curve 0', '1: curve 1', '2: curve 2'.
Curve 0 can be selected only when H8.05 is set to ‘5: -10…10 V’.
When H8.05 is set to ‘0, 1, 2, 3, 4’, curve 1 / curve 2 can be selected.
When H8.05 is set to ‘5: -10…10 V’, curve 0 / curve 1 / curve 2 can be selected.
Bosch Rexroth AG
Functions and Parameters
EFC x610 Series
116/389
DOK-RCON03-EFC-X610***-IT05-EN-P
Содержание EFC 3610 Series
Страница 18: ...Bosch Rexroth AG EFC x610 Series XVI DOK RCON03 EFC X610 IT05 EN P ...
Страница 332: ...Fig 15 15 0020 N 03_0025 N 03 Bosch Rexroth AG Accessories EFC x610 Series 300 389 DOK RCON03 EFC X610 IT05 EN P ...
Страница 333: ...Fig 15 16 0025 A 05 EFC x610 Series Bosch Rexroth AG Accessories DOK RCON03 EFC X610 IT05 EN P 301 389 ...
Страница 336: ...Fig 15 21 0250 N 05 Bosch Rexroth AG Accessories EFC x610 Series 304 389 DOK RCON03 EFC X610 IT05 EN P ...
Страница 421: ...Notes EFC x610 Series Bosch Rexroth AG ...