Measures prior to commissioning
Operating_Manual_Fan_KXE_04_en.docx
67 / 128
Fan configuration with grease-lubricated bearings:
Grease-lubricated bearings are filled with lubricating grease
at the factory and are fully operational.
NOTICE!
The type of grease used is specified on the fan, on
an additional information plate next to the nameplate.
Only this grease type may be used for re-lubrication.
Specifications regarding the re-lubrication intervals
and re-lubrication quantities can be obtained from
this information plate and from chapter 13.2
The lubricating greases to be used in accordance with the
respective requirement are listed as follows:
Requirement
Lubricating grease
For normal climatic conditions,
i.e. ambient temperatures
of -20 °C … +40 °C
SHELL GADUS S2
V100 2
For low temperatures, i.e. ambient
temperatures down to -40 °C
TOTAL MULTIS
COMPLEX
SHD100
Suitable for foodstuffs (FDA
compliant)
Klübersynth UH1
14-222
8.11 Checking the lubricant
Table 8-6
Lubricating greases