Product description
Operating_Manual_Fan_KXE_04_en.docx
23 / 128
Additional instructions for fans pursuant to Directive
2014/34/EU (ATEX):
Any modification on the fan will invalidate the declaration of
conformity. The declaration of conformity will retain its
validity in the following exceptional cases:
- Modifications or conversions must be agreed with
REITZ in writing in advance
- Following conversion work, a qualified person performs
all necessary testing, such as gap measurements,
vibration metering, checks for alignment
- This qualified person guarantees that the measuring
results are within the required tolerances
Forward
measurement records to REITZ for approval
- This qualified person guarantees that all possibilities
for the generation of sparks are eliminated and that the
minimum gaps are observed
This qualified person must meet the following requirements:
- Has been assigned by the operating company for
assembly of the components pursuant to §14 and §15
of the German Health and Safety at Work Regulations
- Is able to identify and prevent possible hazards to
persons, as well as material damage to property and
harm to the environment
- Is familiar with utilisation of the measuring equipment
Should you require any assistance, please do not hesitate to
contact us.