Recommissioning
Operating_Manual_Fan_KXE_04_en.docx
117 / 128
If the fan has been out of operation for a period exceeding
3 months, the following procedure is to be observed.
Procedure for recommissioning:
Check the bearings and shaft seals for leaks
If leaks are ascertained, replace the corresponding
components
Ensure adequate filling level of all lubricants
- Oil level for oil bearings
- Filling level of automatic re-lubrication device (where
featured) for grease bearings
- Filling level of automatic re-lubrication device (where
featured) for shaft seals
- Where necessary, top up the oil to ensure optimum oil
level between “min.” and “max.” markings
- Where necessary, replace the grease cartridges of the
automatic re-lubrication devices
Remove the anti-corrosion coating from all bright machine
parts which could impair functioning (e.g. shaft seal, shaft
earthing)
Remove any accumulated water from inside the housing
Remove any condensate from the terminal boxes of motor
and other electrical components, such as actuators
(where featured)
Corroded, damaged or non-functioning components
will impair operational safety of the fan. Only use
components which exhibit a flawless condition.
16. Recommissioning