Maintenance
Operating_Manual_Fan_KXE_04_en.docx
111 / 128
Procedure for replacing and setting the shaft earthing:
Loosen the screw on the retainer slightly
Remove the used carbon brush
Check the setting of the retainer and adjust as required:
- With the carbon brush removed, the retainer may not
make contact with the shaft, retain a minimum gap of
5 mm
Pull back the retainer slightly and insert the carbon brush
Tighten the screw on the retainer
With the carbon brush removed, the retainer may not
make contact with the shaft. Retain a minimum gap
of 5 mm. Never allow sparks to be generated as a
result of abrasion.
NOTICE!
Carbon brushes, retainers and other spare parts can
be ordered from REITZ. Always specify the serial
number of the fan when ordering.
ATTENTION!
Harmful to the environment!
Dispose of all worn carbon brushes and other parts
which are no longer required in an environmentally
friendly manner.
Fig. 13-10 Correct setting
(shaft earthing without
carbon brush)
Fig. 13-9 Measuring the carbon
brush