Decommissioning
Operating_Manual_Fan_KXE_04_en.docx
116 / 128
Variant “grease-lubricated single bearings”:
Apply additional grease to both bearings until fresh grease is
exuded and turn the shaft a few times by hand.
Variant “grease-lubricated multiple bearing blocks”:
Fill the space between housing cover and rolling bearing with
grease and turn the shaft a few times by hand. The grease
quantities below are provided as reference values.
Type
Re-lubrication quantity [g]
ZLG 306
20
ZLG 307
26
ZLG 308
36
ZLG 309
50
ZLG 310
67
ZLG 311
86
ZLG 312
108
ZLG 313
132
ZLG 314
160
ZLG 315
192
ZLG 316
227
ZLG 317
271
ZLG 318
316
ZLG 319
308
ZLG 320
368
ZLG 322
466
ZLG 324
657
NOTICE!
If the time frame for decommissioning is longer than
12 months, condition of the grease must be checked.
Should de-oiling or contamination of the grease be
ascertained, the grease must be replaced
completely.
Table 15-1 Grease-lubricated multi bearing blocks,
re-lubrication for decommissioning