INSTALLATION AND MAINTENANCE 

INSTRUCTIONS 

• Do read the entire instruction leaflet before commencing installation.

• Do install each fan with a means for disconnection in all poles in the fixed wiring.

• Do make sure the mains supply is switched off before attempting to make electrical connections or carry out any maintenance 

or cleaning.

Please leave this leaflet with the fan for the benefit of the user.

Components:

1. Whisper Silent Shower Fan

2. 3m flexible 4” / 100mm ducting

3. External fixed louvre grille with 2 x invisible screw covers

4. 5 x wall plugs

5. 5 x screws

6. 1 x self-adhesive foam strip for duct connection (if required)

UK customers: 

If you have any queries before or after installing this product call the Addvent Technical Hotline 0117 923 5375.  

Our engineers are there to help you during normal office hours. Or you can fax at all other times on 0117 923 5374. 

Customers outside the UK should contact your local Addvent distributor.

Addvent AVX100WIDT  

In Duct Timer Fan  

Shower Kit

Содержание AVX100WIDT

Страница 1: ...the user Components 1 Whisper Silent Shower Fan 2 3m flexible 4 100mm ducting 3 External fixed louvre grille with 2 x invisible screw covers 4 5 x wall plugs 5 5 x screws 6 1 x self adhesive foam strip for duct connection if required UK customers If you have any queries before or after installing this product call the AddventTechnical Hotline 0117 923 5375 Our engineers are there to help you durin...

Страница 2: ...at the electrical rating shown on each fan matches the mains supply THE APPLIANCE IS DOUBLE INSULATED AND DOES NOT REQUIRE AN EARTH CONNECTION All installations must be supervised by a qualified electrician Installations and wiring must conform to current IEE Regulations UK local or appropriate regulations other countries Built in timer that operates the fan for a pre set delay from 30 seconds to ...

Страница 3: ...Back plate fixing positions B Quickfix clamps C D A ...

Страница 4: ...Front Cover Removal Depress Cover Latch with tool remove Cover E Minimum 30 seconds Maximum 30 minutes Factory setting Timer 15 minutes F ...

Страница 5: ...in a kitchen fans must not be mounted immediately above a cooker hob or eye level grill If installing in a room containing a fuel burning device which has a non balanced flue it is the installer s responsibility to ensure that there is enough replacement air to prevent fumes being drawn down the flue when the fan is operating up to maximum extract Refer to Building Regulations for specific require...

Страница 6: ... line marked on it is orientated squarely 3 Carefully insert the fan duct into the prepared hole in the ceiling 4 Mark the positions of the fixing holes in the back plate 5 Remove the back plate 6 Drill screw holes in these positions if necessary and fit wall plugs and screws as required Mount the back plate 7 Feed the mains cable through the cable entry hole in the back plate to the terminals 8 I...

Страница 7: ...ferent applications Select either high or low speed by connecting the jumper between the centre and high or low speed pin on the jumper see Figure G To adjust the over run period turn the control T clockwise to increase and anti clockwise to decrease see Figure F Using the fan Operate the fan using an on off switch not supplied Note the fan may take up to 10 seconds to turn on once the switch has ...

Страница 8: ... Bristol BS11 8HT www addvent co uk 08 100024 0 ISSUE 1 0418 Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your local authority or retailer for recycling advice EXCHANGE WARRANTY YEAR 5 ...