REMOVE AND REPLACE FUEL PUMP FLEXIBLE COUPLING
WORK INPROGRESS
PROCEDURES REQUIRE VERIFICATION
INITIAL SETUP:
Tools and Special Tools
References
General Mechanics Tool Kit
Materials/Parts
Equipment Condition
Drain Pan or Bucket
Equipment Powered Down
Rags
Power
Source
Disconnected
REMOVAL OF FLEXIBLE COUPLING:
1. Remove the fuel pump/solenoid as follows:
a. Disconnect power cord from power supply.
b. Attach drain hose to the fuel water separator bowl drain valve.
c. Open drain valve and drain contents into a waste fuel container.
d. Using a 9/16” open end wrench, loosen and disconnect fuel in-line at fuel water strainer housing.
e. Remove drain hose and retighten drain valve.
f.
Using a 9/16” open end wrench, loosen and disconnect fuel line at the fuel pump/solenoid assembly.
g. Using a 7/16” open end wrench, loosen and disconnect the fuel nozzle tube.
h. Disconnect the solenoid electrical harness plug.
i.
Using a ½” open end wrench, loosen and remove the fuel pump/solenoid assembly (2) mounting
bolts.
j.
Remove fuel pump/solenoid assembly from burner motor housing.
k. Remove the flexible coupler from the fuel pump/solenoid shaft.
Содержание G2 series
Страница 2: ......
Страница 12: ......
Страница 22: ......
Страница 34: ......
Страница 36: ......
Страница 42: ......
Страница 44: ......
Страница 56: ......
Страница 58: ......
Страница 60: ......
Страница 66: ......
Страница 112: ......
Страница 116: ......
Страница 118: ......
Страница 152: ......
Страница 180: ......
Страница 183: ......