INSPECTION AND CLEANING SUCTION TUBE SCREEN PROCEDURES (G2S-I ONLY)
PROCEDURES REQUIRE VERIFICATION
INITIAL SETUP:
Tools and Special Tools
Personnel Required
General Mechanics Tool Kit
One
Materials/Parts
Equipment Condition
Clean
Water
Equipment
Powered
Down
Power
Source
Disconnected
INSPECTION OF SUCTION TUBE SCREEN:
1. Disconnect power cord from power supply
2. Remove suction hose from solution tank.
3. If necessary, loosen and remove suction hose from the lower end of the injector assembly.
4. Slide screen off of suction hose and inspect screen for foreign objects.
CLEANING SUCTION TUBE SCREEN:
5. Clean screen by running clean water backwards through screen.
6. Inspect screen for damages; if necessary replace with a new screen.
7. If unable to clean screen thoroughly, replace with new screen..
REINSTALLATION OF SUCTION TUBE SCREEN:
8. Slide
screen
back
onto suction tube.
9. Reconnect and tighten suction hose on the lower end of the injector assembly.
10. Place suction tube assembly into the solution tank.
11. Reconnect power cord into the power supply.
END OF TASK
Содержание G2 series
Страница 2: ......
Страница 12: ......
Страница 22: ......
Страница 34: ......
Страница 36: ......
Страница 42: ......
Страница 44: ......
Страница 56: ......
Страница 58: ......
Страница 60: ......
Страница 66: ......
Страница 112: ......
Страница 116: ......
Страница 118: ......
Страница 152: ......
Страница 180: ......
Страница 183: ......