Operation & Maintenance w/IPB
G2 Series Decontamination Water Heater
0015
Part Number: 1006375
0015-19
DHS Systems LLC
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.
INJECTOR MAINTENANCE PROCEDURES (G2S-I ONLY)
INITIAL SETUP:
Tools and Special Tools
Personnel Required
General Mechanics Tool Kit
One
Materials/Parts
Equipment Condition
Chlorine
Bleach
Equipment
Powered
Down
Power
Source
Disconnected
NOTE
The following maintenance procedures should be performed after each use of the
Injector Assembly with a Decon solution.
WARNING
Failure to follow these general maintenance procedures of the injector may result in
poor performance from the injector.
WARNING
Incorrect operation of this water heater could result in serious injury and or damage
to the equipment. Do Not alter or modify this water heater in any manner.
RINSE INJECTOR AFTER EACH USE:
NOTE
Additive allowed to remain in injector can dry out and damage lower end at the
next start up
1. Put suction tube into a 1 qt. (4 liters) or more container of fresh filtered water.
2. Pull fresh water through the injector by operating until container is empty.
CLEAN SUCTION TUBE FILTER SCREEN:
Inspect each time new solution is added. Clean as frequently as
necessary by washing in fresh water. Remove filter screen from suction tube and run water backwards through it.
Replace if necessary. Keep filter screen off bottom of solution container to prevent dirt and precipitate from
contamination solution.
CLEAN SOLUTION CONTAINER:
Keep covered to prevent any contaminants from entering container. Rinse
container thoroughly and often. Do not mix chemical together that might react and cause a precipitate. Use
FILTERED WATER when filling container.
CLEAN INLET FILTER:
Clean or replace inlet filter as required to increase the life of the unit as well as reduce
pressure loss.
STORAGE:
For extended storage, rinse injector as described above and place entire injector underwater (in 5 gal
container). Monthly, apply a small amount (thimble full) of chlorine bleach to avoid algae growth.
END OF TASK
Содержание G2 series
Страница 2: ......
Страница 12: ......
Страница 22: ......
Страница 34: ......
Страница 36: ......
Страница 42: ......
Страница 44: ......
Страница 56: ......
Страница 58: ......
Страница 60: ......
Страница 66: ......
Страница 112: ......
Страница 116: ......
Страница 118: ......
Страница 152: ......
Страница 180: ......
Страница 183: ......