Operation & Maintenance w/IPB
G2 Series Decontamination Water Heater
0010
Part Number: 1006375
0010-6
DHS Systems LLC
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.
Table 1. Operator Troubleshooting – Mechanical (Cont).
ITEM
CONDITION/INDICATION
POSSIBLE MALFUNCTION
CORRECTIVE ACTION
Check fuel tank cap.
Fuel tank is over filled.
Tighten fuel tank cap.
Drain excessive fuel from tank.
Check all fuel lines, fuel pump
and filter connections.
Tighten as required
Check if fuel is leaking from
burner, coil housing or
chamber.
Stop heater immediately and
disconnect power supply.
Service burner system
11.
Fuel leaking from unit.
Excess fuel is leaking from
burner chamber
Contact REEVES EMS
(NOTE: See Burner Will Not Ignite
section, Item #2 of this table).
Check for proper fuel in fuel tank
Remove and replace fuel filter
Ensure the burner switch is in the ON
position.
Ensure there is adequate flow.
Check to see if blower motor is
turning:
A) Reset thermal overload on burner
motor.
B) Check for obstruction in the
squirrel cage.
C) Check the fuel bypass return line
for obstructions.
D) Check the fuel pump for binding
12.
No Hot Water.
No heat or flame.
Check for spark across the
electrodes:
A) Remove target assembly from top
of burner.
B) Using a mirror, inspect for spark
across electrodes.
C) If no spark, check for voltage to
ignition transformer (110V unit =
110VAC)
Содержание G2 series
Страница 2: ......
Страница 12: ......
Страница 22: ......
Страница 34: ......
Страница 36: ......
Страница 42: ......
Страница 44: ......
Страница 56: ......
Страница 58: ......
Страница 60: ......
Страница 66: ......
Страница 112: ......
Страница 116: ......
Страница 118: ......
Страница 152: ......
Страница 180: ......
Страница 183: ......