REMOVE AND REPLACE DECON SOLUTION TANK STRAINER (G2-I WATER HEATER ONLY)
INITIAL SETUP:
Tools and Special Tools
Personnel Required
General Mechanics Tool Kit
One
Materials/Parts
Equipment Condition
Clean
Water
Equipment
Powered
Down
Power
Source
Disconnected
REMOVAL OF DECON SOLUTION TANK STRAINER:
1. Disconnect power cord from power supply
2. Disconnect solution hose from the QCD at solution tank.
3. Unscrew solution in-line tube from solution tank.
4. Carefully remove in-line tube from tank; gently pull straight up to remove tube and strainer.
5. Remove strainer from tube.
6. Clean/rinse strainer in clean water.
7. Inspect strainer for damages; if necessary replace with a new strainer.
INSTALLATION OF DECON SOLUTION TANK STRAINER:
8. Install strainer onto in-line tube.
9. Install in-line tube into solution tank; turn solution in-line tube CW and tighten.
10. Reconnect solution hose to the QCD at the solution tank.
11. Reconnect power cord into the power supply.
END OF TASK
Содержание G2 series
Страница 2: ......
Страница 12: ......
Страница 22: ......
Страница 34: ......
Страница 36: ......
Страница 42: ......
Страница 44: ......
Страница 56: ......
Страница 58: ......
Страница 60: ......
Страница 66: ......
Страница 112: ......
Страница 116: ......
Страница 118: ......
Страница 152: ......
Страница 180: ......
Страница 183: ......