INSTALLATION OF THE ELECTRONIC IGNITER ASSEMBLY (CONT):
h. Reinstall the electronic igniter and base plate assembly; ensure the igniter springs are contacting the
electrodes tangs and electrical wires are not pinched.
i.
Using a 5/16” open end wrench, install and tighten (2) hex head screws.
j.
Using a cross-point screwdriver, install and tighten (2) cross-point screws.
k. Reconnect power cord into power supply.
l. Perform
operations
check.
END OF TASK