![Quantum SDLC 2.7 Скачать руководство пользователя страница 138](http://html2.mh-extra.com/html/quantum/sdlc-2-7/sdlc-2-7_installation-manual_3489443138.webp)
132
Advanced Setup Instructions
Step 2
Resolve the library SCSI IDs:
•
Single-aisle:
•
On the library Operator panel, do the following:
Main > Setup > Library > SCSI > Target ID
.
•
Set the SCSI IDs on both buses to 3.
•
Restart the library so that the SCSI IDs take effect.
•
Dual-aisle (Scalar 10K DA):
•
On the Operator panel for Robot 1 do the following:
Main > Setup > Library > SCSI > Target ID
.
•
Set the SCSI ID on both buses to 3.
•
On the Operator panel for Robot 2 do the following:
Main > Setup > Library > SCSI > Target ID
.
•
Set the SCSI ID on both buses to 4.
•
Restart the library so that the SCSI IDs take effect.
Step 3
Connect the library to the host
•
Single-aisle:
•
Standard solution:
•
Connect the SCSI cable to the respective LVD/HVD controller 1 of the library and to the
Scalar DLC SCSI HBA card.
•
On the PC, launch
My Computer > Manage > Device Manager
to verify that the Windows
2000/2003 machine can see the Library "Medium Changer".
•
Failover and Self-domain solution:
•
Connect the SCSI cable to the respective LVD/HVD controller 1 of the library and to the
Scalar DLC Node1 SCSI HBA card.
•
Connect the SCSI cable to the respective LVD/HVD controller 2 of the library and to the
Scalar DLC Node2 SCSI HBA card.
•
On both nodes, launch
My Computer > Manage > Device Manager
to verify that the
Windows 2000/2003 machine can see the "Medium Changer" device.
•
Dual-aisle (Scalar 10K DA):
•
Standard solution:
•
Plug Y-block connector with LVD/HVD-terminator to LVD/HVD controller 1 of the Robot 2.
•
Plug the Y-block connector to LVD/HVD controller 1 of the Robot 1.
•
Connect two Y-block connectors of Robot 1 and Robot 2 with the SCSI cable.
•
Connect the free connector of Y-block connector at Robot 1 and the Scalar DLC SCSI HBA
card with the SCSI cable.
CAUTION
Make sure to install the proper voltage SCSI connections (see
Table 19
on
page 115).
CAUTION
Make sure to install the proper voltage SCSI connections (see
Table 19
on
page 115).
Содержание SDLC 2.7
Страница 1: ...InstallationGuide Scalar DistributedLibraryController 2 7...
Страница 6: ...vi Table of Contents...
Страница 14: ...8 System Description...
Страница 56: ...50 Setting Up the Scalar DLC...
Страница 76: ...70 Installing the Scalar DLC...
Страница 82: ...76 DAS Client...
Страница 120: ...114 Upgrade Remove Repair...
Страница 130: ...124 SCSI FC Target Drivers...