![Quantum SDLC 2.7 Скачать руководство пользователя страница 105](http://html2.mh-extra.com/html/quantum/sdlc-2-7/sdlc-2-7_installation-manual_3489443105.webp)
Installation Guide
99
Replacing Old RAID
The following instruction is to be used in order to replace old ADTX RAID (J-series) with the new (P-series)
hardware without removing Scalar DLC system.
Initializing RAID
•
Start from Main Menu and Press O
•
Down arrow to Change Config and Press O
•
Password is 1234
•
Down arrow to Raid Config and Press O
•
Down arrow to LU and Press O
•
Down arrow to Initialize LU and Press O
•
Select LU0 and Press O
•
“Data will be lost” message shows and Press O
•
Down arrow to Yes and Press O, press O
•
Press X five times to show progress
Preparing RAID for Installation
•
Power on RAID and wait for ready light.
•
Press O to enter Main Menu
•
Down arrow to Change Config and press O
•
Password is 1234
•
Down arrow to SCSI and Press O
•
Channel 1 and Press O
•
Set to 0 and Press O
Table 17
Swapping RAID Time Schedule
Procedure
Time
Initializing RAID
on page 99
6 hr
Preparing RAID for Installation
on page 99
15 min
Preparing Scalar DLC for RAID Replacement
on page 100
15 min
Swapping Hardware
on page 101
30 min
Configuring New External RAID
on page 102
1 hr
Verify Correct RAID Changeover
on page 104
10 min
Manually Rebuilding RAID
on page 105
1 hr
CAUTION
The step is to be performed only for the hardware than is NOT fresh-from-
factory. Not required when the RAID is clean and never used before.
Содержание SDLC 2.7
Страница 1: ...InstallationGuide Scalar DistributedLibraryController 2 7...
Страница 6: ...vi Table of Contents...
Страница 14: ...8 System Description...
Страница 56: ...50 Setting Up the Scalar DLC...
Страница 76: ...70 Installing the Scalar DLC...
Страница 82: ...76 DAS Client...
Страница 120: ...114 Upgrade Remove Repair...
Страница 130: ...124 SCSI FC Target Drivers...