Installation Guide
105
Step 2
On active node (Node1) launch
Start > Shutdown > Shutdown > OK
Step 3
Wait for both nodes to power down completely
Step 4
Turn off RAID.
Manually Rebuilding RAID
If a hard disk drive fails in the internal RAID on the SDLC server, the RAID rebuilding process should
automatically restart when the failed hard disk drive is replaced. However, if the RAID rebuilding process
does not automatically restart, the RAID alarms and the new hard disk drive displays two red LEDs. This
can happen if the system is powered off or while the system is in BIOS Setup screen.
Rebuilding the Internal RAID Manually
Step 1
Shut down the applications and reboot the system.
Step 2
When the
Hit for Adaptec Setup, Waiting for devices...”
message displays, press
Ctrl-A
on
your keyboard. The Adaptec message then informs you that the Adaptec Setup will be entered
after POST is complete.
Step 3
After entering Adaptec Setup, use the down arrow key on your keyboard to place your mouse
cursor on the RAID item, and then press
Ctrl-R
to activate the RAID menu.
Step 4
In the RAID menu, select
Rebuild
. The rebuild process begins.
Since the RAID rebuilding process runs in the background, you can exit the RAID BIOS as soon as the
rebuild process begins, but it is recommended that you wail until the drives are in synch before exiting the
RAID BIOS. The rebuild process requires at least one hour.
Back up Scalar DLC Database
There are two almost equivalent methods, use either one. See
Scalar DLC Reference Guide, Tools and
Utilities, Database Tool
for more details.
Backup to a local file
Step 1
On active node right click the penguins in the toolbar. Select
Tools > Scalar DLC DB tool
, then
OK
.
Step 2
Select
Backup
tab,
Manual backup,
and “...” in the Destination area.
Step 3
Specify a temp location on the C: drive. Enter file name and select
Save
.
CAUTION
Do not change the position of the undamaged drive in the RAID. It is
recommended that you replace a failed hard disk drive while the system is
running in normal mode (powered ON and NOT in BIOS Setup screen). The
RAID BIOS is only entirely operative in the normal mode state.
Note
The Rebuild menu will only be active if the system detects that the RAID requires
rebuilding. In this case, the RAID status displays as “Degraded”.
Содержание SDLC 2.7
Страница 1: ...InstallationGuide Scalar DistributedLibraryController 2 7...
Страница 6: ...vi Table of Contents...
Страница 14: ...8 System Description...
Страница 56: ...50 Setting Up the Scalar DLC...
Страница 76: ...70 Installing the Scalar DLC...
Страница 82: ...76 DAS Client...
Страница 120: ...114 Upgrade Remove Repair...
Страница 130: ...124 SCSI FC Target Drivers...