Quantum SDLC 2.7 Скачать руководство пользователя страница 1

Installation Guide 

Scalar

 ® 

Distributed Library Controller

 ™ 

2.7

Содержание SDLC 2.7

Страница 1: ...InstallationGuide Scalar DistributedLibraryController 2 7...

Страница 2: ...out notice COPYRIGHT STATEMENT Copyright 2007 by Quantum Corporation All rights reserved Your right to copy this manual is limited by copyright law Making copies or adaptations without prior written a...

Страница 3: ...ents 10 Dual aisle Requirements 11 Setup Roadmap 12 Collecting Setup Data 12 Setting Up the Host 13 Installing the Scalar DLC Software 15 Configuring the Logical Library 15 Setting Up the Failover Sol...

Страница 4: ...orer 54 Java 2 Runtime Environment 54 Apache HTTP Server 55 Microsoft SQL Server Desktop Engine 2000 55 MSDE 2000 Service Pack 4 56 Scalar DLC Software 56 5 DAS Client 71 Installing DAS Client 71 Inst...

Страница 5: ...leshooting Applications 125 Scalar DLC Installation 125 Scalar DLC Database Utility 126 Scalar DLC Online Help 127 SCSI and Fibre Channel Target Mode Driver 127 SQL Server 127 Client Applications 128...

Страница 6: ...vi Table of Contents...

Страница 7: ...You Might Need The following documents are also available for this product These documents can be found on the product CD or at www quantum com support Scalar DLC Release Notes 6 00335 xx DAS Adminis...

Страница 8: ...website at www quantum com support The website contains a collection of information including answers to frequently asked questions FAQs You can also access software firmware and drivers through this...

Страница 9: ...ar DLC also allows administrators to select parameters that define which library events provide notifications to customers and the Global Call Center GCC via email and Simple Network Management Protoc...

Страница 10: ...e After the library has executed the requested operation the response is sent back to the Scalar DLC indicating that the operation was executed The Scalar DLC server updates the database according to...

Страница 11: ...on page 5 Depending on the library used by the customer the solution and system configuration should be selected as shown in table 2 Table 1 Scalar DLC Platforms OS Platform Service Pack Referred as...

Страница 12: ...an error occurs and the online Scalar DLC host turns offline the other host is immediately online so the user may not even notice there has been a problem with the host and the customer engineer can...

Страница 13: ...patibility Matrix Software Hardware SW FW Level Scalar 10K both single and dual aisle models 320A 00004 SNC 5100 4 45 22 Scalar DLC 2 7 RMU 210A AMC 4 5 1 SNMS StorNext Management System 2 7 LTO 1 5AU...

Страница 14: ...8 System Description...

Страница 15: ...Scalar DLC standard solution can be installed on any Windows 2000 or Windows 2003 based system Check the system requirements Depending on the tape device used with the Scalar DLC Single aisle Require...

Страница 16: ...iate SCSI FC cable s Fibre Channel switch SNC Dual aisle Requirements Figure 2 Scalar DLC Basic Solution Dual aisle The minimum PC system hardware requirements are summarized in following list A singl...

Страница 17: ...llowing hardware not shown on the scheme is optional SCSI FC target adapter s Appropriate SCSI FC cable s Fibre Channel switch SNC Setup Roadmap Complete the following steps to set up the basic soluti...

Страница 18: ...in admin password is required Step 3 Install all required software services for example antivirus packages and firewall Install all required device drivers for example initiator SCSI and RAID Install...

Страница 19: ...he Task Bar when Connected Select Internet Protocol TCP IP and select Properties Select Use the Following IP Address Set IP Address 208 230 5 100 in lab Set Subnet Mask to 255 255 255 0 Set Preferred...

Страница 20: ...K Figure 3 Windows 2003 DNS suffix enabled Set Computer name SDLC Select Domain and enter domain name without postfix and OK domain for lab Enter domain admin name and password and OK adicuser and pa...

Страница 21: ...r the Automatic or Manual configuration option to configure the logical library automatically If more than one logical library should be created select the Advanced configuration option Refer to the C...

Страница 22: ...Power 15 or greater SVGA Display Standard keyboard mouse NT 2000 compliant LVD SCSI initiator adapter RAID connection NT 2000 compliant LVD HVD SCSI initiator adapter library connection 1 ArrayMasSto...

Страница 23: ...ntel Xeon or equivalent CPU 512 MB RAM Dual 18Gb SCSI Hard Drives PERC3 DI 128MB Battery Backed Cache two Internal Channel Embedded RAID Controller 1 2 Drives connected to on board RAID Dual On Board...

Страница 24: ...scheme is optional SCSI FC target adapter s Appropriate SCSI FC cable s Fibre Channel switch SNC Setup Roadmap Complete the following steps to set up the Failover solution 1 Collecting Setup Data on p...

Страница 25: ...ic default Gateway public preferred DNS public alternate DNS optional public primary WINS optional public secondary WINS optional Node1 private IP address Node2 private IP address private subnet mask...

Страница 26: ...ff external RAID Step 2 Insert the RAID SCSI HBA into the PCI slot of Node1 according to Table 18 on page 72 Connect it and RAID SCSI channel S11 with the short SCSI cable Terminate the second RAID SC...

Страница 27: ...se select I will configure the server later and press Next Clear Show This Screen on Startup and close window Step 7 Shutdown Node1 Step 8 Repeat steps 4 to 7 for Node2 Step 9 Connect ethernet cables...

Страница 28: ...VIEW CONFIG VIEW CONFIG SCSI SCSI CHANNEL 1 SCSI ID 0 The same steps for channel 2 In order to change the SCSI ID for both channels use the following steps RAID SUBSYSTEM MAIN MENU MAIN MENU SYSTEM IN...

Страница 29: ...by turning it off Configuring SCSI for RAID and Library Step 1 Plug the SCSI cable directly in to the RAID vhdci connector Step 2 Power on Node1 then power on RAID If Write Signature does not appear t...

Страница 30: ...ontroller Int 13 Support to Disabled NOT scan Press Esc Go to SCSI device configuration see Figure 10 on page 21 Figure 8 Adaptec SCSI Bios SCSI Device Configuration Set Sync Transfer Rate to 40 Set S...

Страница 31: ...tomatic Set Reset SCSI Bus parameter to disabled Set the SCSI ID of this board to 6 Step 5 Log on Update drivers Adaptec QLA etc as described in Updating Drivers on page 110 Step 6 Shutdown Node1 Step...

Страница 32: ...able then right click and Enable A new item Local Area Connection 2 will appear Step 4 Set up Private network Right click Local Area Connection 2 and rename it to Private Select Properties Select Show...

Страница 33: ...OK and OK to reboot and OK and Yes Step 7 Yes to reboot now Wait until reboot Step 8 Repeat steps 1 to 6 for Node2 No to reboot now Step 9 Shutdown both nodes CAUTION Both Node1 and Node2 names must...

Страница 34: ...te Signature Wizard should start Press Next If Write Signature does not appear the RAID is not initialized Return to Step 1 Select Disk 1 to write a Signature and press Next Unselect Disk 1 to Upgrade...

Страница 35: ...Manager and open Disk Drives Scan for new devices Verify that the ADTX RAID is present Select Disk Management Right click RAID Select Change Drive Letter and Path Select Edit and Assign Drive Letter...

Страница 36: ...at Private is at the top of Networks list and Next Set Cluster IP address to ip address 208 230 5 3 in lab Set Subnet Mask to 255 255 255 0 Set Network to Public and Next Finish and OK to Cluster Serv...

Страница 37: ...IP static unique and Next Enter domain user account password Next Review cluster summary and Next Wizard creates a cluster Next and Finish Step 3 Join Node2 to Cluster Power on Node2 and wait till it...

Страница 38: ...y Backup Database None Unselect Turn On Email Notifications Select Complete Select Install immediately for Target Drivers if required Install Java 2 install I accept and Next and Typical and Next and...

Страница 39: ...omain name Set Run as a service for all Users and Next Select Complete and Next and Next and Install and Finish Ok to the system being restarted now and restart 15 min for SQL Remove Scalar DLC Instal...

Страница 40: ...Users and Next Set SDLC User Name to SDLC user name Set password to SDLC user password Select domain account and Check Wait 5 min and Submit Look for successful component registration and Next Set Da...

Страница 41: ...as the domain user with local admin rights Insert Scalar DLC Install CD Close Autorun Run CD Scalar_DLC Cluster SDLC_ClusterConfig exe Verify that both nodes show as up in the SDLC Cluster Configurato...

Страница 42: ...on both nodes Cluster name 14 symbols max IP address Subnet mask public subnet mask Domain name domain admin name and password directory services restore mode password CAUTION The operating system and...

Страница 43: ...me as for the plain Failover solution that described in details in Setting Up the Failover Solution on page 13 Setup Roadmap 1 Collecting Setup Data on page 34 2 Installing the Nodes on page 34 3 Inst...

Страница 44: ...ddress private subnet mask private preferred DNS Node1 private IP private alternate DNS Node2 private IP Local administrator login name and password same on both nodes Scalar DLC serial number same on...

Страница 45: ...ode1 and 192 168 0 221 for Node2 in lab Set Subnet Mask to 255 255 255 0 Set Default gateway to same as static IP of Node1 192 168 0 220 Set Preferred DNS to same as static IP for Node1 192 168 0 220...

Страница 46: ...on Node1 and log in In Configure your server window select Active Directory Select Start the Active Directory Wizard and Next Select new domain and next Select create new domain tree and next Select c...

Страница 47: ...ntroller Node2 In the Configure your server window select Active Directory Select Start the Active Directory Wizard and Next Select additional domain controller and next Enter user name and password a...

Страница 48: ...ward queries and Next Review summary and Next Press OK to confirm restart when needed Choose Public network Unselect Enable security on the selected interface Next for the PC with three and more netwo...

Страница 49: ...r and Next Summary and Next and Next Select Create forward lookup zone for small networks and Next Select An ISP maintains the zone as the Node2 is the secondary DNS and Next Enter the zone name any u...

Страница 50: ...d starts Click Next Select Primary Partition and press Next Set maximum value in Amount of Disk Space to Use and press Next Select Assign a Drive Letter and select R and press Next Select Format this...

Страница 51: ...ext and Next Set up Cluster Network For Network Name public select Enable this Network for Cluster Use Select All Communications mixed network and Next For Network Name private select Enable this netw...

Страница 52: ...6 Ensure the cluster works Select Start Programs Administrative Tools Cluster Administrator Select Groups Cluster Group Select File Move Group to verify the cluster is working properly Move group aga...

Страница 53: ...uster name will be available from Node2 Switch to Node2 Start Administrative Tools Cluster Administrator Choose Open Connection to cluster and enter the cluster name SDLCCLUSTER2003 OK Then File New N...

Страница 54: ...private subnet mask private preferred DNS Node1 private IP private alternate DNS Node2 private IP Local administrator login name and password same on both nodes Scalar DLC serial number same on both n...

Страница 55: ...rs WinZip needs to be installed and is not by default Leave RAID off for a minimum of 20 seconds before powering back on Hang on boot up at ATI Rage SDRAM Bios is not an uncommon condition Immediately...

Страница 56: ...50 Setting Up the Scalar DLC...

Страница 57: ...til all files have been installed Before installing the Scalar DLC perform the Solution Checkup on page 51 Using the Scalar DLC setup engine install the required Software Components on page 52 After t...

Страница 58: ...or newer only for Windows 2000 Java 2 Runtime Environment Java 2 1 4 2_09 Secure Socket layer SSL optional Microsoft SQL Server 2000 Desktop Engine MSDE 2000 MSDE 2000 Service Pack 4 Silent Mode When...

Страница 59: ...t is recommended that you disable the SYN attack detection setting After choosing Software Scalar DLC Install you will be prompted to disable the detection parameters Figure 14 SYN Attack Detection Op...

Страница 60: ...net Explorer tools and services Java 2 Runtime Environment The Java 2 component installs over an existing Java runtime environment without producing a warning message By default the Java 2 is installe...

Страница 61: ...QL Server Desktop Engine 2000 If the Microsoft SQL Server 2000 is installed already it is not required to install the MSDE 2000 If there is either MSDE 7 0 or MS SQL Server 7 0 installed on the PC the...

Страница 62: ...ove Programs engine The MSDE SP4 separately cannot be removed Restart is not required Scalar DLC Software All Setup windows contain the following buttons Back Next Cancel Follow the directions on the...

Страница 63: ...icense Agreement Click Next to proceed to the next screen a copy of Figure 13 on page 52 Proceed only after all of the required components are installed Otherwise the Scalar DLC Installation should be...

Страница 64: ...the domain account and see Figure 24 on page 60 for the registration Figure 21 Create Local User Account Table 5 Personal Information Name Operation Description User name Enter The user name PC owner...

Страница 65: ...on User name Enter User account name SDLC by default User password Enter User account password Confirm Enter Password must be confirmed User account to be created Select Local specifies the account ty...

Страница 66: ...or enter the correct password Figure 24 Component Registration Note Do not use system tools to change the Scalar DLC user account created during installation If a change is made the Scalar DLC system...

Страница 67: ...host name where the database should be created Compact Select The Compact Database schedule can be set here Backup Select The Backup Database schedule can be set here Backup file Enter Default databas...

Страница 68: ...er update it or create a new clean database See Figure 27 on page 62 If a new database is installed the next window Email Notifications settings appears See Figure 28 on page 63 Figure 26 Selecting Da...

Страница 69: ...n page 82 2 2 2 2 SP1 2 2 SP2 2 2 SP3 Upgrade database 2 3 2 3 SP1 2 3 SP2 Upgrade database 2 4 Upgrade database 2 5 2 5 SP1 2 5 SP2 Upgrade database 2 6 Upgrade database 2 7 Use existing database Tab...

Страница 70: ...ftware features that will be installed if some features are not required for example Scalar DLC SCSI Client support See Figure 30 for details Specify the installation type and click Next to proceed Tu...

Страница 71: ...lly Check DAS and NobleNet The DAS Client support Installed optionally Check ROBAR The ROBAR Client support Installed optionally Physical Libraries Supplied Scalar 10K The support of Scalar 10K single...

Страница 72: ...e installation It recommended that you accept the option and installing the drivers If the drivers are installed already decline this option The drivers may be installed later manually as well For the...

Страница 73: ...ter The contact email address SMTP Server Enter The SMTP server name Port Enter The SMTP server port Contact telephone Enter The contact phone number Contact fax Enter The contact fax number Service c...

Страница 74: ...information Figure 34 Email Registration Form The email can be sent to any number of recipients See Table 13 on page 69 for details Table 12 Review Registration Form Name Operation Description Send li...

Страница 75: ...Add Remove Scalar DLC Software on page 77 Table 13 Email Registration Form Name Operation Description From Enter From email address To Enter To email address list of addresses Subject Supplied Not ch...

Страница 76: ...70 Installing the Scalar DLC...

Страница 77: ...ftware on page 56 The server PC requires a restart Step 2 Start the Management GUI Create the library configuration that the client requires Create the required mailboxes and clean scratch pools Creat...

Страница 78: ...installed directly on Scalar DLC host In case of the Redundant solution it should be installed on both cluster nodes Table 14 DAS Variables Variable Explanation DAS_SERVER Network names TCP IP of the...

Страница 79: ...g Firewall Property Operation Description DAS Client connection Select Not using firewall should be selected if there is no firewall between the client host and the Scalar DLC host Using DAS ACI firew...

Страница 80: ...ee Figure 36 on page 72 Launch the DAS Client installation and when the component selection screen appears see Figure 35 on page 71 select a DAS ACI Firewall component See Figure 39 on page 75 for a D...

Страница 81: ...A new software service DAS ACI Firewall appears in system services list Removing DAS Client Using Add Remove Software launch Scalar DLC DAS Client and remove the software Property Operation Descripti...

Страница 82: ...76 DAS Client...

Страница 83: ...n the PC CAUTION For the Failover and Self domain solution make sure that the Add Remove is launched on the active node If not cancel the operation move Cluster group ownership to the current node and...

Страница 84: ...t to proceed Remove The Remove process deletes all of the Scalar DLC software features except for the Scalar DLC account name and password that were set up during installation For installation informa...

Страница 85: ...a 2 MS IE MSDE 2000 and so forth are not removed and should continue to function normally The Remove process also restores the old web server configuration software Repair The Repair process allows th...

Страница 86: ...s and click Next to proceed See Table 15 for details If the Computer renaming mode is selected the Repair checks all needed software components If no software upgrade is needed the Repair process proc...

Страница 87: ...base upgrade engine as the Scalar DLC installation and offers the same functionality Figure 45 Repair Database Choose either the recreate database option to acquire the new clean database or upgrade o...

Страница 88: ...additional actions may be required Depending on the configuration used see Simple Upgrade on page 84 or Advanced Upgrade on page 88 The instructions on which upgrade type is more preferable are locat...

Страница 89: ...are up and running and that Scalar DLC is stopped on both nodes Use the correct Scalar DLC Cluster Configuration utility If Scalar DLC 2 5 is installed use SDLC_ClusterConfig from the Scalar DLC 2 5 C...

Страница 90: ...ge 88 Failover Standard Advanced Upgrade on page 88 Failover Simple Upgrade on page 84 2 6 Standard Standard Simple Upgrade on page 84 Failover Advanced Upgrade on page 88 Failover Standard Advanced U...

Страница 91: ...tely from Scalar DLC itself in descending order Do not reboot now Remove DAS Client software if installed as described in Removing DAS Client on page 75 and SCSI Target Drivers as described in Add Rem...

Страница 92: ...Figure 48 Install Scalar DLC Upgrade database optional Install the required SCSI Target drivers see Installing the SCSI FC Target Drivers on page 118 Then configure activate the SCSI FC Target adapte...

Страница 93: ...ber that the customer may have multiple SCSI Targets Each Target will have LUN 0 in case when a SCSI client exist for the target the LUN 0 will be active with a client assigned to it Figure 50 SCSI co...

Страница 94: ...pgrade is complete verify that all target cards are correctly assigned and work properly Advanced Upgrade Follow these steps to perform the upgrade of the Scalar DLC software on any PC and or to resto...

Страница 95: ...DLC DB Tool and log on see Figure 57 If the Scalar DLC database has been installed under Trusted connection only the local admin rights are required If the Scalar DLC database has been installed unde...

Страница 96: ...LC Hot Fixes mentioned separately from Scalar DLC itself in descending order Do not reboot now Remove DAS Client software if installed as described in Removing DAS Client on page 75 and SCSI Target Dr...

Страница 97: ...Target Drivers on page 118 Then configure activate the SCSI FC Target adapter s via SCSI Target Port Tool as described in Activating Target Mode on page 121 optional Install DAS Client software if re...

Страница 98: ...in previous versions of the Scalar DLC software are still supported Remove old SCSI client s and create new client assigned to an old library if it is required Executing the complete inventory is str...

Страница 99: ...ctions however may be necessary and require the update of most software installed on the appropriate hosts When the Scalar DLC Standard solution is installed after the PC is renamed and or the network...

Страница 100: ...t Network Identification tab and Properties Select More Box and Remove the Primary DNS suffix and OK Enter Domain Name without postfix and OK customerdomain Enter name and Password for Domain user Acc...

Страница 101: ...K Enter Domain Name without postfix and OK customerdomain Enter name and Password for Domain user Account and OK customeracct and customerpass OK when welcome to domain appears OK to reboot computer t...

Страница 102: ...Properties Select Network Identification tab and Properties Enter New computer name and OK SDLC22 Enter name and password for User account customeracct customerpass OK and OK to reboot OK to System P...

Страница 103: ...or domain User account customeracct customerpass OK and OK to reboot OK to System Properties and Yes to restart now Restart Node2 and log on as Administrator for SDLC22 this computer Select Start Butt...

Страница 104: ...xt Select Scalar DLC Server and Next Select Computer Renaming and Next Leave entries alone and Check and Next Verify successful component registration and Next and Install and Finish OK to Fatal Error...

Страница 105: ...reparing RAID for Installation Power on RAID and wait for ready light Press O to enter Main Menu Down arrow to Change Config and press O Password is 1234 Down arrow to SCSI and Press O Channel 1 and P...

Страница 106: ...lication access to Scalar DLC or disconnect Scalar DLC from the library Cluster data Cluster name Cluster IP Address Subnet mask use Cluster Administrator to obtain Instructions Make Node1 active Swit...

Страница 107: ...button Click on the Finish button When prompted select NO to restarting the computer Power off Node2 Click on the Start menu on the tool bar Select Shutdown On the popup window select Shutdown Click...

Страница 108: ...is menu scroll down to SCSI Controller Termination If this is NOT set to Automatic change it as follows Press Enter to bring up a changes menu Scroll up to Automatic Press Enter to save the changes Th...

Страница 109: ...he Start button on the tool bar shutdown the Node1 PC Turn the RAID off Power on Node2 Repeat Step 1 on page 102 for Node2 Step 4 Turn on the RAID and wait for the ready light Join RAID to Node2 as de...

Страница 110: ...gurator and remove Scalar DLC CD Restart both nodes Verify Correct RAID Changeover Start Cluster Administrator program From the menu select Groups Cluster Group Verify that the following resources are...

Страница 111: ...o activate the RAID menu Step 4 In the RAID menu select Rebuild The rebuild process begins Since the RAID rebuilding process runs in the background you can exit the RAID BIOS as soon as the rebuild pr...

Страница 112: ...either floppy disk or folder on RAID disk or network resource to the temp location both local and network resources are allowed using C temp is preferable Step 2 On the active node right click the pe...

Страница 113: ...ies Driver Update Driver on WIndows 2000 also Driver Details button Note that for Adaptec and QLA 2342 there are two channels both are to be updated Figure 60 RAID Adaptec 39160 Driver Win2000 Note Ch...

Страница 114: ...e Adaptec Driver Next Insert Scalar DLC 2 7 CD Select Install driver from a list or specific location The 2003 wizard shall find the driver on CD the 2000 needs to be updated manually Display a list o...

Страница 115: ...that should be replaced is supposed NodeO the new node that replaces NodeO is supposed NodeB NodeA online RAID on NodeO power off Step 1 On active node NodeA evict the damaged node NodeO from the clu...

Страница 116: ...NodeB do Configuring SCSI for RAID and Library on page 23 For Failover solution only for Self domain solution skip this substep For NodeB do Setting Up IP Address Node Name and Joining Domain on page...

Страница 117: ...ng and power on new node One disk fails in the external RAID Step 1 Remove the cover and unlock the disk Step 2 Remove failed disk and insert new disk Step 3 Reconstruction will begin Approximate reco...

Страница 118: ...ssible that manual improvement is needed See Scalar DLC Reference Guide Advanced Configuration section for more details Step 5 After the configuration is performed backup the new database to a archive...

Страница 119: ...p 5 Restore the database as described in Recover database from old backup on page 112 Step 6 After restarting the Scalar DLC launch the complete inventory for a library Note If Java folders are not re...

Страница 120: ...114 Upgrade Remove Repair...

Страница 121: ...f adapters that are currently supported and see Table 20 on page 116 for a match description CAUTION Connecting two adapters that do not match will cause hardware damage Table 19 SCSI and Fibre Channe...

Страница 122: ...tures on a PC without appropriate SCSI adapter In the Management GUI under the SCSI Target tab the Local SCSI Target port appears so the Target objects can be created and assigned to the SCSI Clients...

Страница 123: ...oaded this driver from the manufacturer s web site to the temporary folder You can also access the required drivers at the Scalar DLC Install_CD Drivers Initiator folder Step 2 During setup startup th...

Страница 124: ...nstallation is launched on a PC with the installed target drivers from a previous version for example 2 4 the install engine will remove the old drivers See Add Remove SCSI Target Drivers on page 122...

Страница 125: ...rget Licensing Accept the License Agreement and click Next to proceed Figure 66 Personal Information Enter the customer s personal information See Table 5 on page 58 for the meaning and required opera...

Страница 126: ...rs Figure 68 Local SCSI Target No SIgnature Press Yes and continue the installation ADIC Local SCSI Target driver is not certified by Microsoft no other failures in it are known currently Table 22 Dri...

Страница 127: ...Access to SCSI Target Port Tool The SCSI Target Port tool opens Figure 70 SCSI Target Port Tool adapter disabled Click Enable to enable the required SCSI Adapter s as in the figure below Note After re...

Страница 128: ...r repair the installed Target drivers use the Add Remove build in system engine Control Panel Add Remove Programs SCSI Target Mode Drivers The same engine should be used in order to perform an upgrade...

Страница 129: ...t PC Step 4 After reboot open the autostart screen again Launch the Scalar DLC installation see Scalar DLC Software on page 56 to install both the Scalar DLC software and appropriate SCSI Target drive...

Страница 130: ...124 SCSI FC Target Drivers...

Страница 131: ...27 Client Applications on page 128 Scalar DLC Installation Issue Blue screen after installing drivers for RAID or network adapter Solution Drivers are installed wrong and conflict with the Windows har...

Страница 132: ...on 0x80040E14 cannot add delete or modify a job error when trying to modify the existing backup compact SDLC database schedule Solution This is the MS SQL bug the configured schedule can be changed on...

Страница 133: ...s situation is sometimes encountered when the PC has more than one active PCI slot and the SCSI card that should operate in Target mode is installed in this slot Solution Swap the SCSI Target Adapter...

Страница 134: ...red by Scalar DLC HP Omniback When using Omniback follow the step here Add the following entries to the omnirc file DAS_CLIENT OMNIBACK_C1 DAS_SERVER host where the host is the host name of the machin...

Страница 135: ...arget tab locate all FC adapters that contain more than one Target Step 2 For each such FC adapter for example Adapter 1 locate the Target with minimal SCSI ID for example Target 0 This will be the on...

Страница 136: ...ssing yes button the dialog vanished and the restart is not initiated Solution Ikernel exe object hangs Stop it manually via Windows Task Manager Processes Ikernel exe right click End Process After th...

Страница 137: ...that will be used For the 6 symbols barcode set the Media ID to disabled The library scanner cannot determine different media of a single domain for example DLT IV or SDLT so the media type default by...

Страница 138: ...dows 2000 2003 machine can see the Library Medium Changer Failover and Self domain solution Connect the SCSI cable to the respective LVD HVD controller 1 of the library and to the Scalar DLC Node1 SCS...

Страница 139: ...he SCSI cable to the respective LVD HVD controller 2 of the library and to the Scalar DLC Node2 SCSI HBA card On both nodes launch My Computer Manage Device Manager to verify that the Windows 2000 200...

Страница 140: ...enabled Right click and select Disable or execute Menu Action Disable to disable the library Figure 75 Device Manager Disabled Library Media Changer Ensure that the library device is disabled The Scal...

Страница 141: ...ibrary and its drives are on and all cables are properly connected configure the SNC Use ADIC Management Console AMC to set up the SNC and resolve ports IP connection type zoning and WWN For more deta...

Страница 142: ...is causes the SNC to reboot Step 6 When the SNC has rebooted issue the fcShowNames command to verify the change Verify that the output in the Node Name column is correct If only a single FC port is to...

Страница 143: ...tting Up the Standard Solution on page 9 Setup Roadmap Step 1 Resolve the cabling switch etc Figure 76 and Figure 77 are examples of the whole structure Note also Two channel Adapters on page 116 Step...

Страница 144: ...scheme Figure 80 Failover SNC with the dual aisle switch scheme Figure 81 Failover SNC with the dual aisle two port scheme Requirements Two Scalar DLC servers hosts Node 1 and Node 2 Each host has at...

Страница 145: ...he library robot as not ready Building Client Connections Additional activity may be required for the clients to connect to the Scalar DLC software DAS Install the DAS Client software on the client PC...

Страница 146: ...s on page 116 and Disabling Library Medium Changer on page 141 Figure 83 Standard solution Fibre Channel Client Connection FC Requirements 1 FC Target Adapter as described in Table 19 on page 115 FC s...

Страница 147: ...Failover solution Fibre Channel Client Connection FC Requirements 2 FC Target Adapters as described in Table 19 on page 115 FC switch 2 FC cables client connection Be sure that the client connection s...

Страница 148: ...arget Adapters on a Live Machine Although it is recommended that you install and set up all required hardware before starting the work it is possible to make some changes later too Step 1 Node1 passiv...

Страница 149: ...r the information on securing the MSDE 2000 MS SQL refer to http www microsoft com sql techinfo administration 2000 security securingsqlserver asp The Scalar DLC itself requires the following security...

Страница 150: ...ment system refer to http isservices tcd ie security epol php After the antivirus software is successfully installed provide the regular antivirus database update either by periodical basis or automat...

Страница 151: ...7 Installing Target Drivers 118 SCSI and Fibre Channel Hardware 115 Two channel Adapters 116 Setting Up the Scalar DLC 9 Common Setup Notes 49 Setting Up the Failover Solution 15 Active Directory Acco...

Страница 152: ...Installation 125 Scalar DLC Online Help 127 SCSI and Fibre Channel Target Mode Driver 127 SQL Server 127 U Upgrade Remove Repair 77 Add Remove Scalar DLC Software 77 Modify 81 Remove 78 Repair 79 Down...

Отзывы: