4 – Managing Switches
Displaying Switch Information
4-10
59097-01 A
0
Zoning Default Visibility
Zoning visibility status. Permits (All) or prevents (None)
communication between attached devices in the absence
of an active zone set.
Security Auto Save
N/A - does not apply to this switch
Security Fabric Binding
Enable
N/A - does not apply to this switch
Temperature
Internal switch temperature °C
Fan 1 Status
The status of Fan 1
Fan 2 Status
The status of Fan 2
Fan 3 Status
N/A - does not apply to this switch
Power Supply 1 Status
Power supply 1 status
Power Supply 2 Status
Power supply 2 status
Beacon Status
Beacon status. Switch LEDs are blinking (On) or not (off).
Broadcast Support
Broadcast support status. Broadcast support is enabled or
disabled (default).
In-band Enabled
In-band management status. Permits (True) or prevents
(False) a switch from being managed over an ISL.
Temperature Failure Port
Shutdown
Non-configurable (always enabled for this switch). All
ports are downed when the switch temperature exceeds
the Failure Temperature.
Warning Temperature
Non-configurable temperature threshold (65° Celsius)
above which a warning condition alarm is generated.
Failure Temperature
Non-configurable temperature threshold (70° Celsius)
above which a failure condition alarm is generated.
NTP Client Enabled
Enabled or disabled. Allows for switches to synchronize
their time a centralized server.
NTP Server Address
The IP address of the centralized NTP server. Ethernet
connection to NTP server is required.
FDMI HBA Entry Limit
Maximum number of HBAs that can be registered with a
switch.
Table 4-2. Switch Data Window Entries (Continued)
Entry