P809 Failsafe Time
In the event of a failsafe condition the failsafe timer determines the time
before failsafe mode is activated.
Default = 2mins
If the timer activates, the unit goes into
failsafe
, as determined by
P808
(
Display
),
P218, 228, 238, 248, 258, 268
(
Relays
) and
P840
(
mA Output
).
When this happens, you will see the message “
Failed Safe
!” on the display,
along with a message explaining why (lost echo or transducer fault, for
example).
When a valid measurement is obtained then the display, relays and mA
output will be restored, and the timer is reset.
Auxiliary
P810 Units
This parameter determines whether the
Measurement units
(
P104
) are
displayed on the auxiliary line of the display in run mode.
OPTION
DESCRIPTION
0 = No
Measurement units
will not
be displayed
1 = Yes (Default)
Measurement units
will
be displayed
P811 Alarm Messages
This parameter determines whether notification messages are displayed on
the auxiliary line of the display in run mode when an alarm relay is switched
on or off. The message is in the form “Alarm High ON”, where the ‘High’ is
determined by the setting of the relay
Alarm ID
(
P212, 222, 232
).
OPTION
DESCRIPTION
0 = No (Default)
Alarm messages
will not
be displayed
1= Yes
Alarm messages
will
be displayed
Содержание Zenith 140
Страница 1: ...Zenith 140 Instruction Manual ...
Страница 2: ...2 ...
Страница 14: ...ZENITH 140 INSTRUCTION MANUAL 14 EU Certificate of Conformity ...
Страница 17: ...PULSAR MEASUREMENT 17 Dimensions Fascia Mount The dimensions of the wall fixing holes are as shown below ...
Страница 19: ...PULSAR MEASUREMENT 19 Terminal connection details Fascia Mount The terminal details are as illustrated below ...
Страница 160: ...ZENITH 140 INSTRUCTION MANUAL 160 NOTES ...