PULSAR MEASUREMENT
119
P601-P603 Vessel Dimensions
These three parameters are used to enter the dimension required to
calculate the volume. The dimensions required are as shown below and are
entered
Measurements Units
(
P104
).
VESSEL SHAPE
P601
P602
P603
P600 = 0
Cylindrical flat base
Cylinder
Diameter
Not required Not required
P600 = 1
Rectangular flat base
Not required
Width of
rectangle
Breadth of
rectangle
P600 = 2
Cylindrical cone base
Height of
base
Width of
rectangle
Not required
P600 =3
Rectangular pyramid base
Height of
base
Width of
rectangle
Breadth of
rectangle
P600 = 4
Cylindrical parabola base
Height of
base
Cylinder
diameter
Not required
P600 = 5
Cylindrical half sphere base
Cylinder
diameter
Not required Not required
P600 = 6
Cylindrical flat sloped base
Height of
base
Cylinder
diameter
Not required
P600 = 7
Rectangular flat sloped base
Height of
base
Width of
rectangle
Breadth of
rectangle
P600 = 8
Horizontal cylinder flat ends
Length of
cylinder
Cylinder
diameter
Not required
P600 = 9
Horizontal cylinder parabolic
ends
Length of
cylinder
Cylinder
diameter
Length of
one end
P600 = 10
Sphere
Sphere
diameter
Not required Not required
P604 Calculated Volume
This parameter displays the maximum volume that has been calculated by
the Zenith and is a Read Only parameter. The volume displayed will be
shown in cubic meters and is the total volume available between
empty
level
(
P105)
and 100% of
span
(
P106
).
Содержание Zenith 140
Страница 1: ...Zenith 140 Instruction Manual ...
Страница 2: ...2 ...
Страница 14: ...ZENITH 140 INSTRUCTION MANUAL 14 EU Certificate of Conformity ...
Страница 17: ...PULSAR MEASUREMENT 17 Dimensions Fascia Mount The dimensions of the wall fixing holes are as shown below ...
Страница 19: ...PULSAR MEASUREMENT 19 Terminal connection details Fascia Mount The terminal details are as illustrated below ...
Страница 160: ...ZENITH 140 INSTRUCTION MANUAL 160 NOTES ...