Stratum Installation and Maintenance Guide
Chapter 4: Troubleshooting
••••
75
Restoring Factory Defaults
-------------- VT-100 --------------
To restore factory default settings, choose
[Utilities..]
from the main menu to view the Utilities menu.
------------------------------- Utilities ------------------------------
System Status: OPERATE - CONNECTED - OK NEW [ Alarms & Events.. ]
------- Local -------- ------ Remote -------
ODU Version
Boot ROM: 01.01a 01.01a
Firmware: 01.01e 01.01e
Hardware: 0xA3 0xA3
IDU Version
SCNM Boot ROM: 01.01i 01.01i
SCNM Software: 01.01f 01.01f
DP Boot ROM: 00.20 00.20
DP Software: 00.21 00.21
Framer: 33 33
Hardware: X13B X13B
[ Update ] [ Restore Defaults ] [ Device Reset ]
[ ^Cancel ]
Choose
[Restore Defaults]
and then choose
[Device Reset]
to restart the Stratum unit.
------- Web Browser/HTML ------
To restore factory default settings, click the
Utilities
entry on the left-hand side of the browser screen and choose
Restore Defaults
. Then, choose
Device Reset
to restart the Stratum unit.
Do
NOT
use the
Restore Defaults
option while in Antenna Aiming mode; this will damage the unit. If
you accidentally issue a
Restore Default
command while in Antenna Aiming mode, contact Proxim
Technical Support to obtain a Return Merchandise Authorization (RMA) number and instructions on
how to return the unit for repair.