Chapter 3: Maintaining the Stratum
••••
62
Stratum Installation and Maintenance Guide
Setting Security Parameters
Setting Passwords for Access Levels
The Stratum provides four access levels:
Access Level
Privileges
Superuser
Access to all features.
Maintenance
Temporary access to all functions except passwords. This
password always expires after 24 hours.
Operator
Access to all fields except passwords, SNMP community
strings, IP security, link setup, and system utilities.
User
Read-only access to main menu and reports.
Each access level functions like a user login name and provide different access privileges. Each access level can be
controlled via a password. When logging in to the system, enter an access level and the corresponding password.
-------------- VT-100 --------------
---------------------------- Stratum System Passwords -------------------------
System Status: OPERATE - CONNECTED - OK [ Alarms & Events.. ]
---- User ID ---- ---- Password ----
SuperUser: [wavespan ]
Maintenance: [ ]
Operator: [wavespan ]
User: [wavespan ]
[ ^Apply ] [ ^OK ] [ ^Cancel ]
------------------------------------------------------------------------------
To set the password for an access level, choose
[System Admin..]
from the main menu. Then, choose
[Passwords..]
and the System Passwords screen will appear as shown below.
From this screen, specify passwords for each access level and choose
Apply
to save changes.
If passwords are lost, contact Proxim Technical Support for assistance in gaining access to the Stratum.