![Porsche 2015 911 GT3 Cup Скачать руководство пользователя страница 281](http://html1.mh-extra.com/html/porsche/2015-911-gt3-cup/2015-911-gt3-cup_technical-manual_1580085281.webp)
Electrical System
Level 2 alarms
Every level 2 ALARM is labeled as ALARM. If the message has lower priority “WARN”
appears in the display, together with the error description.
Priority Alarm
Channel
Conditions
Description
3
Fuel
pressure
MS4 pfuel
<2.5 bar (36 psi)
for 5 sec.
Engine speed
more than 2000
rpm
4
Oil
temperature
MS4 toil
>140°C (284 °F)
for 5 sec.
5
Water
pressure
MS4 pwat
<0.35 bar (5 psi)
for 10 sec.
Engine speed
more than 5000
rpm
Water temperature
at least 68 °C
(154 °F)
Vehicle is moving
6
Battery
Battery
Voltage
<11.5 V for 5 sec. Engine speed
more than 2000
rpm
7
Water level
Engine
Sensor on
Digital 15
After 5 sec.
Alarm/warning with lower
priority:
The two lower LEDs of the
display are lit.
6.6.7.7
6.6.7.8
Version: 16.12.2014