E-77
Replacing the Lamp Cartridge
5
Mount the new lamp cartridge.
(1) Placing the lamp cartridge with its socket facing to-
wards you, slowly press the lamp cartridge in.
(Line it up with the screw holes in the projector.)
(2) Turn the two lamp cartridge screws clockwise to
tighten them.
6
Mount the lamp cover.
(1) Set the tip of the lamp cover in place, then close the
lamp cover.
(2) Turn the lamp cover’s screw clockwise to tighten it.
7
Reset the lamp hour meter.
First connect the power cord and turn on the power.
From the menu, select “Projector Options”
→
“Setup”
→
“Page 4”
→
“Clear Lamp Hour Meter” to reset the hour meter.
See “Clear Lamp Hour Meter” on page E-55.
Note:
If the projector is used another 100 hours after the lamp’s service life is reached, the power will no longer turn on. If this happens, in the
standby mode press the HELP button on the remote control unit for at least 10 seconds to clear the remaining lamp time setting and the lamp
hour meter. If the STATUS indicator turns off, the remaining lamp time setting and the lamp hour meter have been cleared.
Purchase a replacement lamp from a store that sells the U2-X2000. Indicate you need a U2-200 replacement lamp for the U2-X2000 (order
code 28-320).