– 203 –
NWA-008845-001 Rev.5.0
32ch1004.fm
DESCRIPTION
DATA
Provide the calling number development and
specify its Development Pattern for each
Number Conversion Block number assigned
by CM76 Y=00/90.
NOTE:
For non-DID on ISDN, Caller ID
calls, this data is not effective and
the data setting of CM35 Y=174 is
effective.
•
(1)
(2)
Y=26
000-999: Number Conversion Block No.
assigned by CM76 Y=00/90
0: To provide
(Using Development Pattern 0)
1: To provide
(Using Development Pattern 1)
2: To provide
(Using Development Pattern 2)
Assign the Development Block number for
each calling party number.
•
•
•
(1)
(2)
Y=50 Development Pattern 0 assigned by
CM76 Y=26
Y=51 Development Pattern 1 assigned by
CM76 Y=26
Y=52 Development Pattern 2 assigned by
CM76 Y=26
X-XX....XX: Calling Party No. (Maximum
16 digits)
X: 0-9
000-999: Development Block No.
NOTE
NOTE:
Set the different number from the
Number Conversion Block
number assigned by CM76
Y=00/90.
Select the two kinds of mode change or the
four kinds of mode change per each tenant.
•
(1)
(2)
Y=29
00-63: Tenant No.
0 : Two kinds of mode (Day Mode, Night
Mode)
1 : Four kinds of mode (Day Mode, Night
Mode, Mode A, Mode B)
Assign the station tenant for each calling party
number.
•
(1)
(2)
Y=09
000-999: Development Block No. assigned
by CM2A Y=50/51/52
00-63: Station Tenant No.
A
CM76
CM2A
CM65
CM76
B
CID CALL ROUTING
Содержание SOPHO 2000 IPS
Страница 2: ......
Страница 10: ...viii ...
Страница 36: ... 18 NWA 008845 001 Rev 5 0 32ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 151: ... 133 NWA 008845 001 Rev 5 0 32ch1002 fm BROKER S CALL PROGRAMMING Refer to CALL HOLD Page 404 BROKER S CALL ...
Страница 276: ... 258 NWA 008845 001 Rev 5 0 32ch1005 fm DIAGNOSTICS PROGRAMMING Refer to the Maintenance Manual DIAGNOSTICS ...
Страница 319: ... 301 NWA 008845 001 Rev 5 0 32ch1006 fm HARDWARE REQUIRED 4DIT card DID Trunk DIRECT INWARD DIALING DID ...
Страница 858: ... 840 NWA 008845 001 Rev 5 0 32ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006 ...