– 639 –
NWA-008845-001 Rev.5.0
32ch1010.fm
DESCRIPTION
DATA
Specify the maximum accumulation rate of
billing memory for external alarm output when
the rate exceeds assigned value.
(1)
(2)
229
0
: 80%
50-99: 50-99%
NOTE 1:
The condition for external alarm is as follows;
(a) The accumulation rate for the following limit value approaches the value set by
CMD001>229 in advance.
(b) The accumulation rate for the following limit value approaches full.
(c) The accumulation rate for the following limit value is less than the assignable range
set by CMD001>229 or is cleared the stored billing memory.
[Limit Value]
- Limit value of remaining Call Record memory set by CMD003>24/29
NOTE 2:
ON/OFF control for external relay on DK00 card and fault information display can be per-
formed with the condition for external alarm as above.
For case (a): External relay ON/OFF set by CMD000>126
Fault information display set by CMEA Y=2>28
For case (b): External relay ON/fault information display set by CMEA Y=2>28
For case (c): External relay OFF/fault information display set by CMEA Y=2>38
C
CMD001
D
JULY/01/2006
STATION MESSAGE DETAIL RECORDING (SMDR)
PROGRAMMING
Содержание SOPHO 2000 IPS
Страница 2: ......
Страница 10: ...viii ...
Страница 36: ... 18 NWA 008845 001 Rev 5 0 32ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 151: ... 133 NWA 008845 001 Rev 5 0 32ch1002 fm BROKER S CALL PROGRAMMING Refer to CALL HOLD Page 404 BROKER S CALL ...
Страница 276: ... 258 NWA 008845 001 Rev 5 0 32ch1005 fm DIAGNOSTICS PROGRAMMING Refer to the Maintenance Manual DIAGNOSTICS ...
Страница 319: ... 301 NWA 008845 001 Rev 5 0 32ch1006 fm HARDWARE REQUIRED 4DIT card DID Trunk DIRECT INWARD DIALING DID ...
Страница 858: ... 840 NWA 008845 001 Rev 5 0 32ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006 ...