– 127 –
NWA-008845-001 Rev.5.0
32ch1002.fm
AUTOMATIC RECALL
PROGRAMMING
DESCRIPTION
DATA
Specify the timing for AUTOMATIC RE-
CALL.
If no data is set, the following timing will be
applied:
Attendant Recall
: 31.2-33.6 seconds
Non Exclusive Hold : 60-64 seconds
Exclusive Hold
: 236-240 seconds
Transfer Recall
: 24-28 seconds
Attendant Hold Recall: 31.2-33.6 seconds
Camp-On Recall
: 24-32 seconds
•
(1)
(2)
Y=0
00: Attendant Recall
01-14: 2.4-33.6 seconds
(2.4 second increments)
15-24: 38.4-124.8 seconds
(9.6 second increments)
(1)
(2)
05: Non Exclusive Hold
01-98: 4-392 seconds
(4 second increments)
99
: Recall is not performed
(1)
(2)
06: Exclusive Hold
01-98: 4-392 seconds
(4 second increments)
99
: Recall is not performed
(1)
(2)
07: Transfer Recall
01-30: 4-120 seconds
(4 second increments)
(1)
(2)
11: Attendant Hold Recall
01-14: 2.4-33.6 seconds
(2.4 second increments)
15-24: 38.4-124.8 seconds
(9.6 second increments)
(1)
(2)
26: Camp-On Recall
01-15: 16-128 seconds
(8 second increments)
START
CM41
END
AUTOMATIC RECALL
Содержание SOPHO 2000 IPS
Страница 2: ......
Страница 10: ...viii ...
Страница 36: ... 18 NWA 008845 001 Rev 5 0 32ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 151: ... 133 NWA 008845 001 Rev 5 0 32ch1002 fm BROKER S CALL PROGRAMMING Refer to CALL HOLD Page 404 BROKER S CALL ...
Страница 276: ... 258 NWA 008845 001 Rev 5 0 32ch1005 fm DIAGNOSTICS PROGRAMMING Refer to the Maintenance Manual DIAGNOSTICS ...
Страница 319: ... 301 NWA 008845 001 Rev 5 0 32ch1006 fm HARDWARE REQUIRED 4DIT card DID Trunk DIRECT INWARD DIALING DID ...
Страница 858: ... 840 NWA 008845 001 Rev 5 0 32ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006 ...