– 655 –
NWA-008845-001 Rev.5.0
32ch1010.fm
DESCRIPTION
DATA
Assign maximum number of Call Record sent
to SMDR terminal 0.
(1)
(2)
0
0
: Not record
1-23580: 1 call-23580 calls
Assign maximum number of Call Record sent
to SMDR terminal 1.
(1)
(2)
1
0
: Not record
1-23580: 1 call-23580 calls
NOTE 1:
When the data is set to 1-23580, external alarm of memory overflow is available if CM44
2nd data=3001 (for CMDD02>0)/CM44 2nd data=3002 (for CMDD02>1) or CMEA
Y=2>28
, 38 is assigned.
NOTE 2:
The amount of call record number set by CMDD02>0, 1, 2 must not exceed the following
number.
NOTE 3:
CMDD02>0, 1, 2 are effective after executing CMDD98. Before executing CMDD98, be
sure to print out all of the stored call records. CMDD98 deletes all of the stored call
records.
E
CMDD02
Amount of Call Records number of CMDD02 1st data 0, 1, 2
No EXPMEM on AP00 is provided
EXPMEM on AP00 is provided
CMDD00>3 is set to 0
(Local Office of
Centralized Billing-
CCIS/Stand-alone)
CMDD00>3 is set to 1
(Center Office of
Centralized Billing-
CCIS)
CMDD00>3 is set to 0
(Local Office of
Centralized Billing-
CCIS/Stand-alone)
CMDD00>3 is set to 1
(Center Office of
Centralized Billing-
CCIS)
2620
1310
23580
22270
F
DECEMBER/02/2005
STATION MESSAGE DETAIL RECORDING (SMDR)
PROGRAMMING
Содержание SOPHO 2000 IPS
Страница 2: ......
Страница 10: ...viii ...
Страница 36: ... 18 NWA 008845 001 Rev 5 0 32ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 151: ... 133 NWA 008845 001 Rev 5 0 32ch1002 fm BROKER S CALL PROGRAMMING Refer to CALL HOLD Page 404 BROKER S CALL ...
Страница 276: ... 258 NWA 008845 001 Rev 5 0 32ch1005 fm DIAGNOSTICS PROGRAMMING Refer to the Maintenance Manual DIAGNOSTICS ...
Страница 319: ... 301 NWA 008845 001 Rev 5 0 32ch1006 fm HARDWARE REQUIRED 4DIT card DID Trunk DIRECT INWARD DIALING DID ...
Страница 858: ... 840 NWA 008845 001 Rev 5 0 32ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006 ...