– 719 –
NWA-008845-001 Rev.5.0
32ch1011.fm
DESCRIPTION
DATA
Assign the Echo Canceller function to each
AMP pattern.
•
(1)
(2)
Y=02
00-14: AMP pattern No. 00-14
0 : Through
1 : Normal
Assign the Gain Controller of Echo Canceller
to each AMP pattern.
•
(1)
(2)
Y=03
00-14: AMP pattern No. 00-14
0 : ON
1 : OFF
Select the mode of Tone Disabler on each
AMP pattern.
•
(1)
(2)
Y=04
00-14: AMP pattern No. 00-14
0 : G164
1 : G165
Specify the detect timing of Tone Disabler on
each AMP pattern.
•
(1)
(2)
Y=05
00-14: AMP pattern No. 00-14
0 : 0 second
1 : 2 seconds
Specify the channels connected to each AMP
pattern.
•
(1)
(2)
Y=06
00-14: AMP pattern No. 00-14
0 : Incoming Route: Tie Line
Outgoing Route: C.O. Line
1 : Incoming Route: C.O. Line
Outgoing Route: Tie Line
Specify the timing of AMP trunk connection
on each AMP pattern.
•
(1)
(2)
Y=07
00-14: AMP pattern No. 00-14
0 : When dialing is finished
1 : When answering
A
CM38
END
TRUNK-TO-TRUNK CONNECTION
Содержание SOPHO 2000 IPS
Страница 2: ......
Страница 10: ...viii ...
Страница 36: ... 18 NWA 008845 001 Rev 5 0 32ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 151: ... 133 NWA 008845 001 Rev 5 0 32ch1002 fm BROKER S CALL PROGRAMMING Refer to CALL HOLD Page 404 BROKER S CALL ...
Страница 276: ... 258 NWA 008845 001 Rev 5 0 32ch1005 fm DIAGNOSTICS PROGRAMMING Refer to the Maintenance Manual DIAGNOSTICS ...
Страница 319: ... 301 NWA 008845 001 Rev 5 0 32ch1006 fm HARDWARE REQUIRED 4DIT card DID Trunk DIRECT INWARD DIALING DID ...
Страница 858: ... 840 NWA 008845 001 Rev 5 0 32ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006 ...