To provide the AMP trunk for Trunk-to-Trunk Connection:
DESCRIPTION
DATA
Assign the card number of the AMP trunk
(AMP card).
NOTE:
The AMP card number must be as-
signed to both of the first LEN (Lev-
el 0) and the third LEN (Level 2) of
each slot.
(1)
(2)
000-763: LEN
Card No. of AMP trunk
For PIM0/1: C100-C115
For PIM2/3: C116-C131
For PIM4/5: C132-C147
For PIM6/7: C148-C163
Assign the card number of the AMP trunk
(AMP card).
[Series 3200 R6.2 software required]
NOTE:
The AMP card number must be as-
signed to both of the first LEN (Lev-
el 0) and the third LEN (Level 2) of
each slot.
(1)
(2)
XX ZZZ: LEN
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
Card No. of AMP trunk
For FP No. 00: C100-C115
For FP No. 01: C116-C131
For FP No. 02: C132-C147
For FP No. 03: C148-C163
Assign the AMP patterns to each combination
of the trunk routes.
•
(1)
(2)
Y=00
XX ZZ
XX: 00-63: Incoming trunk route
ZZ : 00-63: Outgoing trunk route
00-14: AMP pattern No. 00-14
15
: Not use the AMP trunk
Assign the gain value of each AMP pattern.
•
(1)
(2)
Y=01
00-14: AMP pattern No. 00-14
X Z
X: AGC (Automatic Gain Control)
0 : 0 dBr
1 : +4 dBr
2 : –4 dBr
3 : Through (assigned by Fixed Gain)
Z: Fixed Gain
0 : 12 dB
1 : 8 dB
2 : 4 dB
3 : 0 dB
START
CM10
CM14
CM38
A
TRUNK-TO-TRUNK CONNECTION
Содержание SOPHO 2000 IPS
Страница 2: ......
Страница 10: ...viii ...
Страница 36: ... 18 NWA 008845 001 Rev 5 0 32ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 151: ... 133 NWA 008845 001 Rev 5 0 32ch1002 fm BROKER S CALL PROGRAMMING Refer to CALL HOLD Page 404 BROKER S CALL ...
Страница 276: ... 258 NWA 008845 001 Rev 5 0 32ch1005 fm DIAGNOSTICS PROGRAMMING Refer to the Maintenance Manual DIAGNOSTICS ...
Страница 319: ... 301 NWA 008845 001 Rev 5 0 32ch1006 fm HARDWARE REQUIRED 4DIT card DID Trunk DIRECT INWARD DIALING DID ...
Страница 858: ... 840 NWA 008845 001 Rev 5 0 32ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006 ...