DATA
Assign MF Receiver sensitive level.
•
(1)
(2)
Y=1
1: MF Receiver Sensitive level
00-14: –21 dBm- –35 dBm
15
: –36 dBm (–1 dBm increments)
Assign MF Receiver to each circuit number (0-
3) of the MF Receiver Trunk.
•
(1)
(2)
Y=2
0-3 : AP No.
NOTE
3 : All circuits assigned as Receiver
NOTE:
AP numbers 0-3 correspond to the AP
numbers assigned by CM05 (04-15,
20-31):
CM31 Y=2
CM05 Y=0
AP Number 0: AP Number X
AP Number 1: AP Number Y
AP Number 2: AP Number Z
AP Number 3: AP Number W
(X<Y<Z<W)
Assign supervisory timer of interdigit pause on
incoming signal.
•
(1)
(2)
Y=B
05: Supervisory Timer of Interdigit Pause
on Incoming Signal
NONE : 24 seconds
01-31
: 1-31 seconds
Assign Busy/Idle information not to be sent to
T1 network.
•
(1)
(2)
Y=48 Busy/Idle Sending to T1 Network
00-63: Trunk Route No.
0: Not available
A
CM31
INITIAL
INITIAL
CM35
END
AUTOMATIC NUMBER IDENTIFICATION (ANI)
Содержание SOPHO 2000 IPS
Страница 2: ......
Страница 10: ...viii ...
Страница 36: ... 18 NWA 008845 001 Rev 5 0 32ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 151: ... 133 NWA 008845 001 Rev 5 0 32ch1002 fm BROKER S CALL PROGRAMMING Refer to CALL HOLD Page 404 BROKER S CALL ...
Страница 276: ... 258 NWA 008845 001 Rev 5 0 32ch1005 fm DIAGNOSTICS PROGRAMMING Refer to the Maintenance Manual DIAGNOSTICS ...
Страница 319: ... 301 NWA 008845 001 Rev 5 0 32ch1006 fm HARDWARE REQUIRED 4DIT card DID Trunk DIRECT INWARD DIALING DID ...
Страница 858: ... 840 NWA 008845 001 Rev 5 0 32ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006 ...