– 694 –
NWA-008845-001 Rev.5.0
32ch1011.fm
DESCRIPTION
DATA
Specify the value of the Tie Line Pad of
ODT card.
•
(1)
(2)
Y=19
00-63: Trunk Route No.
0-3 : Programmable PAD (See CM42)
4-7 : Fixed PAD (See the following Ta-
ble)
F
CM35
T/R: Transmit/Receive
+ : Gain
– : Loss
CONNECTION PATTERNS
(A-B)
PAD DATA OF B TRUNK
DATA=4 (T/R)
DATA=5 (T/R)
DATA=6 (T/R)
DATA=7 (T/R)
Station-ODT (4W E&M)
–
3/
–
3
–
3/
–
3
Tone-ODT (4W E&M)
0/0
0/0
COT/DID/ODT (2W E&M)/IPT-
ODT (4W E&M)
–
2/
–
2
0/0
ODT (4W E&M)-ODT (4W E&M)
0/0
0/0
DTI/BRT/PRT/CCT/Virtual IPT-
ODT (4W E&M)
0/0
0/0
Station-ODT (2W E&M)
–
3/
–
3
0/0
Tone-ODT (2W E&M)
0/0
0/0
COT/DID/ODT (2W E&M)/IPT-
ODT (2W E&M)
0/0
0/0
ODT (4W E&M)-ODT (2W E&M)
0/0
0/0
DTI/BRT/PRT/CCT/Virtual IPT-
ODT (2W E&M)
0/0
0/0
G
TIE LINES