– 291 –
NWA-008845-001 Rev.5.0
32ch1005.fm
DESCRIPTION
DATA
Specify the various timing for the DTI trunk, if
required.
•
(1)
(2)
Y=3
04: Ringing Signal Detect Timing
01-15: 32-480 ms. (32 ms. increments)
If no data is set, the default setting is 192 ms.
•
(1)
(2)
Y=3
05: Release Signal Detect Timing
01-15: 64-960 ms. (64 ms. increments)
If no data is set, the default setting is 512 ms.
•
(1)
(2)
Y=3
06: Answer Signal Detect Timing
01-15: 64-960 ms. (64 ms. increments)
If no data is set, the default setting is 576 ms.
•
(1)
(2)
Y=3
07: Ringing Signal Detect Time out
01-15: 512-7680 ms. (512 ms. increments)
If no data is set, the default setting is 7,168 ms.
•
(1)
(2)
Y=3
08: Guard Timing of DTI release
01-15: 128-1920 ms. (128 ms. increments)
If no data is set, the default setting is 512 ms.
•
(1)
(2)
Y=3
09: Hooking Signal sending timing
01-15: 64-960 ms. (64 ms. increments)
If no data is set, the default setting is 640 ms.
D
CM41
E
JULY/01/2006
DIRECT DIGITAL INTERFACE
PROGRAMMING
Содержание SOPHO 2000 IPS
Страница 2: ......
Страница 10: ...viii ...
Страница 36: ... 18 NWA 008845 001 Rev 5 0 32ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 151: ... 133 NWA 008845 001 Rev 5 0 32ch1002 fm BROKER S CALL PROGRAMMING Refer to CALL HOLD Page 404 BROKER S CALL ...
Страница 276: ... 258 NWA 008845 001 Rev 5 0 32ch1005 fm DIAGNOSTICS PROGRAMMING Refer to the Maintenance Manual DIAGNOSTICS ...
Страница 319: ... 301 NWA 008845 001 Rev 5 0 32ch1006 fm HARDWARE REQUIRED 4DIT card DID Trunk DIRECT INWARD DIALING DID ...
Страница 858: ... 840 NWA 008845 001 Rev 5 0 32ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006 ...