Section 5-9-5
5-9-5 US Sensor FX (Multifeed detection)
- Refer to Section 3-5 for the part number of the replacement part.
- Refer to Appendix for the specification of the screws.
<Removal>
Remove the imprinter (option).
fi-6140/fi-6130 with Imprinter Referring to Section 8-6-4 “Removing Imprinter”, remove the Imprinter.
Remove Flatbed.
fi-6240/fi-6230 Referring to Section 5-7 “Removing Flatbed,” remove the Flatbed.
1. Remove Chuter Unit.
(1) Referring to Section 5-8-1 “Chuter Unit (ADF Paper Chute),” remove the Chuter Unit.
2. Remove Control PCA.
(2) Referring to step (2) of Section 5-11 “Control PCA,” remove the Control PCA.
3. Remove Base Unit Cover.
(3) Referring to steps (3) ~ (7) of Section 5-9-1 “Base Unit,” remove the Base Unit Cover.
4. Remove OPT Unit.
(4) Referring to step (4) of Section 5-9-6 “OPT Unit (for front side scanning),” remove the OPT Unit.
5. Remove US Sensor FX.
(5) Remove three screws A (circles below) of the US Shield and the FG plate, and then remove the US Shield.
(6) Disconnect the US Sensor FX cable (circle below), and then remove the US Sensor FX.
Note: Do not pull the cable too hard.
US
シールド
US Sensor FX
US Shield
US Sensor FX
FG plate