Section 7-2-1
7-2 Daily Care
As a guideline, clean the ADF every 5,000 scanned sheets. The scanner must be cleaned more frequently when the
following documents are used.
- Documents of coated paper
- Documents with printed text or graphics almost covering the entire surface
- Chemically treated documents such as carbonless paper
- Documents containing a large amount of calcium carbonate
- Documents written by pencil
- Documents on which the toner is not fused sufficiently
Note: Do not use point thinner or other organic solvents instead of ethyl alcohol.
7-2-1 Cleaning the ADF
How to clean:
1. Open the ADF by pushing on the ADF open lever and turning the
ADF cover to the front.
Be careful, the ADF cover may close and pinch your finger.
2. Clean the following locations with a soft, dry cloth or a cloth moistened with cleaning fluid (ethyl alcohol).
No.
Item
1
Brake rollers (x2)
2
Feed rollers (x2)
3
Eject rollers (x2)
4 Glasses
(x2)
5
Pick rollers (x2)
6 Plastic
rollers
(x4)
7 Ultrasonic
sensor
The glass surface of the ADF becomes very hot during the operation of the scanner.
Before you start to clean the inner parts of the scanner, disconnect the AC adapter from the
power outlet, and wait for at least 15 minutes to let the glass cool down.
Do not turn off the scanner when you clean the Feed and Eject rollers.
ADF
Open
lever