Section 5-3-3
5-3-4 Glass inside of Flatbed fi-6240/fi-6230
Follow the procedure below to clean the glass inside of the Flatbed.
07
1)
Referring to Section 5-12-7 “Lamp (fi-6240/fi-6230),” remove the Lamp.
1) Referring to Section 5-12-1, remove the FB Top cover.
2)
Clean inside of the glass of the OPT BOX Unit FB Top Cover with a cloth moistened with alcohol. Be sure that no
fabric from the cloth remains on the glass surface and that the glass is cleaned evenly.
3)
After cleaning, install the Lamp in the reverse order of removal.
1. Take care not to damage the Lamp as it is thin.
2. Conduct the procedure under dust-free environment.
3. Do NOT apply external force to the OPT frame, Mirror, Mirror holder and CCD board.
5-3-5 White reference inside of Base Unit
Follow the procedure below to clean the white reference inside of the Base Unit.
1)
Referring to Section 5-9-4 “Lamp (fro front side scanning),” remove the Lamp.
2)
Rotate the white reference sheet of the Base Unit 90 degrees, and clean it with a cloth moistened with alcohol or a
blower brush. Be sure that no fabric from the cloth remains on the white reference sheet and that white reference sheet
is cleaned evenly.
3)
After cleaning, install the Lamp in the reverse order of removal.
1. Take care not to damage the Lamp as it is thin.
2. Conduct the procedure under dust-free environment.
3. Do NOT apply external force to the OPT frame, Mirror, Mirror holder and CCD board.
5-3-6 White reference inside of Upper Unit
Follow the procedure below to clean the white reference inside of the Upper Unit.
1)
Referring to Section 5-10-6 “Lamp (for backside scanning),” remove the Lamp.
2)
Rotate the white reference sheet of the Upper Unit 90 degrees, and clean it with a cloth moistened with alcohol or a
blower brush. Be sure that no fabric from the cloth remains on the white reference sheet and that white reference sheet
is cleaned evenly.
3)
After cleaning, install the Lamp in the reverse order of removal.
1. Take care not to damage the Lamp as it is thin.
2. Conduct the procedure under dust-free environment.
3. Do NOT apply external force to the OPT frame, Mirror, Mirror holder and CCD board.