Section 5-10-6
5-10-6 Lamp (for backside scanning)
Refer to Section 3-4 for the part number of the replacement part.
<Removal>
1. Remove Chuter Unit.
(1) Referring to Section 5-8-1 “Chuter Unit (ADF Paper Chute),” remove the Chuter Unit.
2. Remove Panel PCA cable.
(2) Referring to steps of Section 5-10-9 “Panel PCA,” disconnect the Panel PCA cable.
Note: There is no need to save EEPROM data.
3. Remove Top Cover.
(3) Referring to steps (3) ~ (5) of Section 5-10-11 “Top Cover,” remove the Top Cover.
4. Remove OPT Unit.
(4) Referring to step (4) of Section 5-10-4 “OPT Unit (for backside scanning),” remove the OPT Unit.
5. Remove Lamp.
(5) - Remove the thin Lamp cable from six BK Cover hooks (circles below).
- Disconnect the Lamp cable from the Inverter (square below).
BK Cover
Thin Lamp cable
Thick Lamp cable