[Display after adjustment]
After the magnification adjustment, the following display appears depending on its terminated status.
(1) When the magnification adjustment is terminated normally
Screen T21
Function No.
Display
Scanner status
Displays “o” (lower half) without blinking.
<Available buttons at screen T21>
Function button: Displays screen T22 to write the correction value into EEPROM.
Send to button: Terminates this mode and returns to screen T04.
Screen T22
Function No.
Display
Scanner status
“o” (lower half) blinks.
<Available buttons at screen T22>
Scan/Stop
+ Function button: Starts writing the magnification correction value into EEPROM. During writing operation, screen
T23 displayed, and when it finishes, screen T24 appears.
Send to button: Terminates this mode and returns to screen T04.
Screen T23
Function No.
Display
Scanner status
“L” lights without blinking.
Note: While screen T23 is displayed, no button can function.
Screen T24
Function No.
Display
Scanner status
“o” (upper half) lights without blinking.
<Available buttons at screen T24>