![PFU Limited fi-6130 Скачать руководство пользователя страница 149](http://html1.mh-extra.com/html/pfu-limited/fi-6130/fi-6130_maintenance-manual_1535731149.webp)
08
July 27, 09 K.Okada
A.Miyoshi I.Fujioka
Refer to Revision Record on page 2.
TITLE
fi-6140/fi-6240/fi-6130/fi-6230/fi-614PR
Maintenance Manual
07
Nov.12, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
CUST.
06
Mar.10, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
DRAW
No.
P1PA03540-B0XX/6
Rev. DATE DESIGN CHECK APPR. DESCRIPTION
Design
July 27, 2007
K.Okada
CHECK
K.Okada
APPR.
T.Anzai
PFU LIMITED
Page
149
/
257
Section 5-12-7
<Installation>
Follow the removing procedure in reverse.
(1) - Install the Lamp to the frame, and then route the thin Lamp cable on the groove of the frame.
- Connect the Lamp cable to the Inverter (solid circle below).
(2) Install the reflector to the frame.
Note: Make sure that the protrusions of the reflector are inserted into the holes of the frame.
Note: Perform the following adjustments after replacing the parts.
- Referring to Section 6-1-3 “Maintenance Mode #2,” adjust the magnification.
- Referring to Section 6-1-4 “Maintenance Mode #3,” adjust the offset.
- Referring to Section 6-1-5 “Maintenance Mode #4,” adjust the white level.
Reflector
Screw A on the
reflector
Reflector
Reflector
Reflector
Thin Lamp cable
Frame groove
Lamp
Lamp
Lamp cable