![PFU Limited fi-6130 Скачать руководство пользователя страница 124](http://html1.mh-extra.com/html/pfu-limited/fi-6130/fi-6130_maintenance-manual_1535731124.webp)
08
July 27, 09 K.Okada
A.Miyoshi I.Fujioka
Refer to Revision Record on page 2.
TITLE
fi-6140/fi-6240/fi-6130/fi-6230/fi-614PR
Maintenance Manual
07
Nov.12, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
CUST.
06
Mar.10, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
DRAW
No.
P1PA03540-B0XX/6
Rev. DATE DESIGN CHECK APPR. DESCRIPTION
Design
July 27, 2007
K.Okada
CHECK
K.Okada
APPR.
T.Anzai
PFU LIMITED
Page
124
/
257
Section 5-10-8
5-10-8 Sensor EMP (Paper empty detection)
Refer to Section 3-20 for the part number of the replacement part.
<Removal>
1. Remove Chuter Unit.
(1) Referring to Section 5-8-1 “Chuter Unit (ADF Paper Chute),” remove the Chuter Unit.
2. Remove Panel PCA cable.
(2) Referring to steps of Section 5-10-9 “Panel PCA,” disconnect the Panel PCA cable.
Note: There is no need to save EEPROM data.
3. Remove Top Cover.
(3) Referring to steps (3) ~ (5) of Section 5-10-11 “Top Cover,” remove the Top Cover.
4. Remove Sensor EMP.
(4) - Unlatch two claws (squares below) from the right side of the Sensor EMP at first, and then remove the Sensor EMP.
- Remove the Sensor EMP cable (circle below).
<Installation>
Follow the removing procedure in reverse.
Note: Make sure that the claws at both sides of the Sensor EMP are securely latched.
After replacing the part, perform the sensor test by referring to Section 6-1-2 “Maintenance Mode #1.”
Sensor EMP
1
2
Sensor EMP