08
July 27, 09 K.Okada
A.Miyoshi I.Fujioka
Refer to Revision Record on page 2.
TITLE
fi-6140/fi-6240/fi-6130/fi-6230/fi-614PR
Maintenance Manual
07
Nov.12, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
CUST.
06
Mar.10, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
DRAW
No.
P1PA03540-B0XX/6
Rev. DATE DESIGN CHECK APPR. DESCRIPTION
Design
July 27, 2007
K.Okada
CHECK
K.Okada
APPR.
T.Anzai
PFU LIMITED
Page
87
/
257
Section 5-9-4
5-9-4 Lamp (for front side scanning)
Refer to Section 3-4 for the part number of the replacement part.
<Removal>
Remove the imprinter (option).
fi-6140/fi-6130 with Imprinter Referring to Section 8-6-4 “Removing Imprinter”, remove the Imprinter.
Remove Flatbed.
fi-6240/fi-6230 Referring to Section 5-7 “Removing Flatbed,” remove the Flatbed.
1. Remove Chuter Unit.
(1) Referring to Section 5-8-1 “Chuter Unit (ADF Paper Chute),” remove the Chuter Unit.
2. Remove Control PCA.
(2) Referring to step (2) of Section 5-11 “Control PCA,” remove the Control PCA.
3. Remove Base Unit Cover.
(3) Referring to steps (3) ~ (7) of Section 5-9-1 “Base Unit,” remove the Base Unit Cover.
4. Remove OPT Unit.
(4) Referring to step (4) of Section 5-9-6 “OPT Unit (for front side scanning),” remove the OPT Unit.
5. Remove Lamp.
(5) Unlatch seven claws (circles below) on the BK Cover to remove the BK Cover.
BK cover
Lamp cable
BK cover